GAS DETECTOR

 

(Combustible Gas Detector, Refrigerant Leak Detector, Natural Gas Detector, Gas Leak Detector, Gas Leakage Detector)

 

Regarding gas detectors questions and answers:

1, Gas Detector is a gas detecting device, not an gas analyzer. It only can detect if there is gas leakage (for LED alarming models) or the leaking concentration (for LCD showing models). While gas analyzer is using for analyzing which kind gas are leaking or how much concentration of each gas in that place, where there are many gases are combined. If you need a gas analyzer, our below models are gas detectors, they are not your needing.

2, For combustible gas detector (excluding multi-gas detector), it is very useful for us to know where you use and which kind main gas (target gas) you want to detect in that place. We need to know this information to calibrate the gas detector by that gas during production. This gas detector after calibrated is more sensitive to that gas, while not very sentitive to other gases.

For example, we can't make it both for natural gas and LPG calibrated when producing, because gas sensor is with selectable feature. It means one gas sensor on gas detector only can be calibrated to test one kind main gas. If we make it both for natural gas and LPG, it is not professional, and will affect the sensitivity of the gas detector. If only for one target gas, the gas detector will be with highest sensitivity.

Yes, our gas detector can be used to detect different combustible gas (EX gas), but it can be utmostly sensitive to only one kind combsutible gas, while not very sensitive to other EX gases.

If user/buyer doesn't tell us the target gas detected, we generally calibrate the gas detector by target gas as natural gas or LPG.

 

For gas alarm separately, please click here: gas alarm

For gas valve, please click here: gas valve

For gas sensor, please click here: gas sensor

NAME: Carbon Monoxide Meter AR818 (NEW)

 

MODEL: AR8700A (AR818)


GENERAL FEATURES &SPECIFICATIONS
-Operation Temperature: 0ºC~ 50ºC
-Storing Temperature: -30ºC ~ 60ºC
-Operating Humidity: 0-99% Relative humidity (Non-condensing)
-Measurement Range: 0-1000PPM
-Measurement Resolution: 1PPM
-Accuracy: 5% or ±10PPM
-Warm Up Period: >2 S


PACKING INFORMATION
Power 9V Battery(6F22)
Product Net Weight: 162g
Product Size: 158.5x59.2x41mm
Packing Gift box

click it for big picture

 

HSTBX166   Pen type Gas Detector   (for private/commercial application)
Brief Introduction:
HSTBX166 series gas detector is specially used for detecting combustible gas leakage. With high-sensitivity and reliable catalytic gas sensor, it is suitable to home, industrial and other environment with methane and propane combustible gas.
The detector has the visual and audible indication for fault, low battery and alarm. It has fashionable appearance, easy to carry and operate.
Features:
-Auto zero calibration
-Fast response and resume
-Easy to operate
-Variety sound for different alarms
-Small zero drift and wide range of operating temperature

Specifications:
-Detecting gas: combustible gas like natural gas, LPG etc.

Models:

HSTBX166 natural gas  : mainly for natural gas

HSTBX166 LPG  : mainly for LPG.

When you order, please let us know specific model.
-Detecting range: 0~100%LEL
-Sampling: natural diffusion
-Working condition: Temperature: -20~55°C Humidity: <95%RH
-Operating voltage: DC3V (two 1.5V AA battery)
-Working current: 139mA
-Alarming level:Low alarm: (20±5) %LEL  High alarm: (50±10) %LEL
-Response time: <5s
-Alarm method: Visual and audible alarm
-Alarm sound: ≥65dB

 

HST80/HST81   Pen type Gas Detector
Features:

-Sensitive, jamproof;
-Best for home application;
-Three types of indications, easy operation;
-long battery life;
-auto shutdown.

MODEL

HST80

Detection

natural gas, LPG, goal gas and etc..

Sensor

planar semiconductor

Warm up time

within 60 seconds

Rnage of detection

CH4: 0 ~ 100% LEL

Alarm Frequency

2.713kHz / 30ms

2.713kHz / 100ms

Range of alarm

~2% LEL (LED Yellow)

~10% LEL (LED Red)

Alarm time

within 20 seconds

Alarm mode

LED, buzzer

Working temperature

-20C ~ 70C

Working humidity

less than 90% RH

Power source

AA 1.5V * 2

Dimension

220 * 20 * 20 mm

Weight

approx. 80g

 

HST82   Pen type Halogen Gas Detector

Features

Sensitive, jamproof
Best for home application
Three types of indications, easy operation
long battery life
auto shutdown

MODEL

HST82

Detection

R11, R113, R134A, R409A, R410A, Freon, alcohol, Nh4, Toluene and Acetone

Sensor

planar semiconductor

Warm up time

within 60 seconds

Rnage of detection

CH4: 0 ~ 100% LEL

Alarm Frequency

2.713kHz / 30ms

2.713kHz / 100ms

Range of alarm

~10ppm (LED Orange) R134A

~80ppm (LED Red) R134A

Alarm time

within 20 seconds

Alarm mode

LED, buzzer

Working temperature

-20C ~ 70C

Working humidity

under 90% RH

Power source

AA 1.5V * 2

Dimension

220 * 20 * 20 mm

Weight

approx. 80g

 

HST8800A+   Combustible Gas detector
This highly reliable broad range combustible gas detector HST8800A+ is an extremely useful tool in any environment where gasoline, propane, natural gas, fuel oil and many other explosive gases may be present.
As a combustible gas or vapor source is approached, an audible signal increases in frequency and the red lights illuminate in sequence, to show the intensity of the leak. Now you can see and hear your way to pinpointing dangerous leaks. The unique flexible probe gives you access to gas leaks in hard to reach places.
Features:
-Ergonomic model, nice handheld touch;
-LCD and buzzer alarms;
-Self faulty detection of sensor during startup;
-Li cells employed, recharing anywhere.

MODEL

HST8800A+

Detection

natural gas, LPG, artificial goal gas and etc..

Sensor

planar semiconductor

Warm up time

less than 60 seconds

Alarm

20Hz ~ 5KHz

Range of alarm

~1% LEL LED1 flashing, without buzzer

~2% LEL LED2 flashing, with buzzer

~5% LEL LED3 flashing, with buzzer

~10% LEL LED4 flashing, with buzzer

~20% LEL LED5 flashing, with buzzer

Alarm mode

LED, buzzer

Working temperature

-20C ~ 70C

Working humidity

less than 90% RH

Power source

Li cell 3.7V 1100mA/h

Indication of charge

10% red LED1

20% red LED2

30% red LED3

40% red LED4

50% red LED5

Indication of sensitivity

Level 0, red LED3

Level -1, red LED2

Level -2, red LED0

Level +1, red LED4

Level +2, red LED5

Dimension

275 * 70 * 30 mm

Weight

approx. 220g

 

HST5750A+  Halogen Gas Detector
Features:
-Ergonomic model, nice handheld touch;
-LCD and buzzer alarms;
-Self faulty detection of sensor during startup;
-Li cells employed, recharing anywhere.

MODEL

HST5750A+

Detection

Freon, benzene, alcohol, acetone

Sensor

planar semiconductor

Warm up time

less than 60 seconds

Alarm

20Hz ~ 5KHz

Range of alarm

~1% LEL LED1 flashing, without buzzer

~2% LEL LED2 flashing, with buzzer

~5% LEL LED3 flashing, with buzzer

~10% LEL LED4 flashing, with buzzer

~20% LEL LED5 flashing, with buzzer

Alarm mode

LED, buzzer

Working temperature

-20C ~ 70C

Working humidity

less than 90% RH

Power source

Li cell 3.7V 1100mA/h

Indication of charge

10% red LED1

20% red LED2

30% red LED3

40% red LED4

50% red LED5

Indication of sensitivity

Level 0, red LED3

Level -1, red LED2

Level -2, red LED0

Level +1, red LED4

Level +2, red LED5

Dimension

275 * 70 * 30 mm

Weight

approx. 220g

 

Combustible Gas Meter HST880 (under development)

Features

  • Easy to read 6999 count backlit displays natural gas, LPG, goal gas levels from 0 to 6000ppm

  • record logging (3 sets)

  • visible and audible alarm >= 500ppm

  • zero point adjustable, gas provision stored permanently

  • auto power off, buzzer raised on 30 seconds before power off

  • 3.7V 650mAh Li cells employed, recharging anywhere

  • data hold

  • low battery warning

MODEL

HST880

Detection

natural gas, LPG, goal gas.

Sensor

thermal linear semiconductor sensor

Range of detection

0 ~ 6000ppm

Bootup time

<= 20 seconds

Alarm frequency

200Hz ~ 5kHz

Range of alarm

>= 500ppm

Alarm mode

LED, buzzer

Working temperature

0°C ~ 50°C

Working humidity

under 90% RH

Power Source

Li cell 3.7V 650mA/h

Battery Indication

LCD displayed

Auto Power Off

10 minutes after standby (buzzer alarm in last 30 seconds)

Dimension

275 * 70 * 30 mm

Weight

approx. 220g

 

Carbon Monoxide Meter HST881

Features

  • Easy to read 6999 count backlit displays carbon monoxide gas levels from 0 to 1000ppm

  • record logging (3 sets)

  • visible and audible alarm >= 40ppm

  • zero point adjustable, gas provision stored permanently

  • auto power off, buzzer raised on 30 seconds before power off

  • 3.7V 650mAh Li cells employed, recharging anywhere

  • data hold

  • low battery warning

MODEL

HST881

Detection

carbon monoxide (CO)

Sensor

electrical chemistry sensor

Bootup time

<= 20 seconds

Range of detection

0 ~ 1000ppm

Resolution

1ppm

Accuracy

5% or 10ppm

Alarm frequency

200Hz ~ 5kHz

Range of alarm

>= 40ppm

Alarm mode

LED, buzzer

Working temperature

0°C ~ 50°C

Working humidity

under 90% RH

Power Source

Li cell 3.7V 650mA/h

Battery Indication

LCD displayed

Auto Power Off

10 minutes after standby (buzzer alarm in last 30 seconds)

Dimension

275 * 70 * 30 mm

Sensor Life time

>= 5 years

Weight

approx. 220g

 

HSTJL269 Portable Gas Detector with Gooseneck   (for industrial/detecting application)
Brief Introduction:

HSTJL269 gas detector for industrial use has a high performance and wide detecting range. It can be used to detect methane, natural gases, propane, LPG, Hydrogen and other combustible gases and find the gas leaking point easily.
Features:
-Calibration-free on gas sensor
-Quick response to combustible gas leakage
-Long and flexible gooseneck tube
-Adjustable sensitivity
-30-level LED / tricolor show
-Battery low voltage alert
-Sensor fault self test

Specifications:
-Detecting Gas: Natural gas, LPG
-Sensitivity: better than 50ppm
-Detection range:
Green LED: 500ppm---10000ppm
Yellow LED: 1000ppm---100000ppm
Red LED: 2000ppm----200000ppm
-Working condition: Temperature. -40°C~70°C Humidity: ≤95% RH
-Warm-up time: <20S
-Response time: <10S
-Indication: 30 levels of LED indication
Green: low concentration
Yellow: middle concentration
Red: high concentration
-Alarming levels: The shorter the frequent buzzer sound, the higher the concentration reach
-Power supply: Ni-H chargeable battery DC3.6V 1600mAh
-Charge time: 4~6 hours
-Using time of the battery: >8h
-Weight: about 310g
-Dimensions: L*W*H 170mm×62mm×26mm

 

HSTGPT100 Portable Gas Detector with Gooseneck   (for industrial/detecting application)

Brief introduction:

Intrinsically safe gas detection equipment

Can detect gas leakage of many combustible gases on many spots

Suitable for using near the pipelines and a valve where there is possibly gas leakage and explosion-proof is required

With GPS function, convenient to record the exact area of the gas leakage and to make detailed record on the maintenance of the pipeline

With excellent imported semi-conductor gas sensor, has good sensitivity; with built-in MCU and friendly operation interface, operation is easy, function is complete, performance is reliable, has multi self adaptation functions

With high distinguishing rate STN lattice LCD, the indication is so clear

With high-intention plastic and multriple anti-slip rubber, the housing has high intention Handle, waterproof and dustproof

Functions and features:

With advanced and lower-consumption 16 digit MCU

High distinguishing rate STN lattice LCD

Adjustable sensitivity and zero point when detecting gas leakage

High-level protection function of the gas sensor

Self-testing function and self-resume function

Battery low voltage alert

Standard Beijing time indication

Auto zero calibration, easy to calibrate it

Intrinsically safe

Technical data:

Detection range: (0 to 10,000) ppm (for CH4)

Target gas: combustible gas

Response time: T<5s

Indication way: LCD and digital indication

Audible indication

Working condition: Temperature: -20 to 60 deg. C

Humidity: <95% RH No con.

Working voltage: DC 3.6V/2100mAh Lion battery

Charging time: 4 to 6 hours

Working time: 12 to 70 hours

Life of gas sensor: 2 years

Protection grade: IP54

Weight: approximately 300g (battery included)

Dimensions: 170 x 77 x 33mm

HSTBX170-LCD with ATEX  single gas detector (for industrial/monitoring application)
Brief Introduction:

HSTBX170 portable single gas detector can make continuous detection to combustible and toxic gases. It is suitable for combustible and toxic gas leakage detection in underground pipe or mines, and keeps the workers safe, prevents the facilities from being destroyed.
The detector, adopting excellent-quality sensor, makes detection in the way of natural diffusion. It has good sensitivity and reproducibility. The detector adopts embedded MCU controller, easy to operate.
The shell adopts special high strength material and anti-smooth rubber, with the characters of water-proof and dust-proof.
Features:
-Advanced MCU control with low power consumption;
-Low and high alarm level;
-Adjustable calibrating level;
-Excessive high concentration protection function;
-High concentration protection for combustible gas;
-Self test for the combustible gas sensor;
-Low battery indication;
-Replaceable sensor module;
-Self-adjustment function
-Visual and audible alarm with vibration;
-STEL and TWA alarming for toxic gases
-Advanced self-examination and self-renovation function
-Password management to avoid wrong operation;
-Explosive proof housing

Specifications:
-Gas Detected: combustible gas(CH4,C3H8,H2)and toxic gas, oxygen, Other rare toxic gas like ammonia, NO, PH3, NH3, NO2, HCN, SO2 etc also available,Can be specified by the Customer in advance.
-Accuracy:≤±5% F.S. Response time:T<30s
-Indication:LCD indicates the time and state
-Indication of alarm, fault and low voltage with LED, sound, vibration
-Operating Environment:
Operating temperature -40°C~70°C (for combustible gas)
Operating temperature: -20°C~50°C (for toxic gas)
-Humidity: < 90%RH non-condensing
-Operating voltage: DC3.6V Li battery; 1200mAh
-Working time: Combustible gas: ≮ 8h continuously Toxic gas: ≮300h continuously
-Charging time: 4h~6h
-Sensor life: 2 years Protection category: IP65

Weight: about 200g (including battery)
Dimension: 110mm*60mm*40mm

   

HSTBX172    Portable single gas detector   (for industrial/monitoring application)
Brief Introduction:

HSTBX172 portable gas detector can make continuous detection for combustible and toxic gases. It is suitable for combustible and toxic gas in underground pipe or mines, keeping your work safely and profitably.
With pump sampling and different length of sampling probes, it is convenient for detecting in different environment. The high and low alarm levels are adjustable (STEL and TWA alert for toxic gas). User can turn on or off the vibration alarm function when necessary. When gas concentration reaches or exceeds the preset alarming level, it will give visible and audio alarm, and backlit is activated automatically. The relative indication help user realize the alarming type. The mark in the LCD makes the operation simple and convenient.
Features:
-Advanced 16 digit MCU control
-Large LCD display
-Built-in pump to sampling, could sample test from long distance
-Low and high alarm can be specified display alarm type
-Display STEL and TWA level
-Supply time and remain battery level display
-Replaceable sensor module
-2000 pieces records, including peak value, type, could auto cover when it full
-Could connect with computer and output data, and analyses the results (software disk is standard delivery), RS232 interface
-Two alarming level, three ternary alarming (visible audio and vibration)
-Power on and self-test function, sensor, visible, audio and vibration information
-Password management and password validation for important operation

Specifications:
-Safe degree: Intrinsically safe
-Sampling: pump sampling
-Sensor: Catalytic or electrochemical
-Gas: Combustible or toxic gas, CO/H2S/O2
-Response time: T<30s
-Operating condition: Temperature -40°C~70°C for combustible gas
-Temperature: -20°C~50°C for toxic gas
-Humidity: < 90%RH non-condensing
-Protection category:IP65
-Battery: DC3.7V, 2.1AH, Li battery
-Working time: 8 hours continuously for catalytic gas sensor
-48hours continuously for electrochemical gas sensor
-Charging time:(4~6)h

 

HSTBX258   Portable Two-gas Detector    (for industrial/monitoring application)
(Gas and CO, H2S, O2 optional,
but can't detect H2S & O2 both by one detector)
Features:

-Colorful screen indication
-Excessive high level protection
-Replaceable sensor module
-Self-adjustment function
-Intrinsically-safe &explosive-proof
Specification:
-Sensor: Catalytic or electrochemical
-Detecting Gas:
flammable Gas, H2, CO, H2S, O2 (two gas from them)
-Alarming: Can be specified
-Accuracy: ±5% F.S
-Response Time: <30s
-Indication: Audio, Visual, Vibration alarm;
-Working Condition: Tem. -40°C~70°C; Hum. <90%RH
-Working Voltage: DC3.6V Li-ion battery; 1200mAh
-Charging Time: 3h~5h
-Working Time: ≥8h continuously
-Life of Sensor: 2 years
-Protection Degree: IP65
-Weight: 200g (Battery included)
-Dimension: 110mm×60mm×40mm

user manual

 

HSTBX616  Portable multi-gas detectors    (for industrial/monitoring application)
Features:

Color LCD display
High-concentration protection and fault self-test
Indications of time, power and low battery
Replaceable sensor module
Auto calibration
Alarm point and calibrating point can be adjusted, auto calibrating point can be set by computer
Detecting activation mode and calibrating activation mode, avoiding wrong operation
Two alarm points with audible, visual and vibrating indication
Serial communication.

Could connect with computer and output data, and analyses the results (software disk is standard delivery); Min USB terminal connects to the interface on the bottom of the detector, and DB9 terminal connects to COM port of computer).
One button operation, easy to operate
Double rubber craftwork, anti-slip, strength to endure

Specifications:

◆ Gas sampling method: Natural diffusion
◆ Gas sensor type: Catalytic and electrochemical
◆ Detecting gas: Combustible gas, H2S, CO, O2 (can test 4 gases together)
◆ Accuracy: ≤±5% F.S.
◆ Response Time: ≤30s
◆ Indication: LCD displays real-time and system status;
◆ LED, audio and vibration alert for gas leakage, fault and low voltage
◆ Power Source: DC3.6V Li-on battery, 1800mAh
◆ Charging time: ≤ 6h
◆ Working time: ≥ 8h continuously (without alarming)
◆ Gas Sensor Life: 2 years
◆ Explosion-proof grade: Ex ibd IICT3
◆ Protection Grade: IP65

Weight: about 200g (including battery)
Dimensions: 65 * 110 * 30mm
Applications:
Oil and gas, steel refinery industry
Coal mine
Communication, chemical
Underground coal mine, pipeline and explosive area

 

NEW and HOT SALES !

 

HSTZQ168 Portable Biogas Detector

Brief introduction

HSTZQ168 portable biogas analyzer, adopting NDIR detecting principle, is used

to analyze the CH4 and CO2 during the biogas processing. At the same, with

external PH sensor, it can also analyze the PH level of the biogas fluid. By

combining tip detecting technology and simple operation, this device has the

advantages of high accuracy, good stability and excellent craftwork etc.

Main function and features:

Adopting advanced low-consumption 16-digit MCU;

128*128 color screen and humanization operation menu;

Self test function after being activated, self diagnosis and self renovation;

Intrinsically safe design to avoid explosion inside the device;

Universal charging hole, so the charger of the standard mobile can be used.

Calibration points can be adjusted, so the user can calibrate it easily;

Advanced long-life NDIR gas sensor;

Audio, video and vibration alarm;

Low voltage alert;

Password management for important operation;

Simple self calibration program;

Adopting high-strength plastics with skidproof rubber, the housing is intense,

good-handle, waterproof, dustproof and shockproof.

Technical specifications

Target gas: Household biogas

Sampling method: Natural diffusion

Gas sensor: NDIR

Detecting range: CH4: 0~100%vol; CO2: 0~50%vol; PH: 0.0~14.0

Alarm level: The user can set it in the detecting range.

Error: CH4/CO2: ≤±5% F.S; PH: ±0.2PH

Response time: <30s

Indication: LCD displays the real time and status; Audio, video and vibration alarms

Working condition: Temperature: -20°C~55°C; Humidity: <95% dews Air pressure: 86 kPa~106 kPa

Power supply: Lithium battery DC3.6V 1800mAh

Charging time: 4~8h

Working time: Not less than 8 hours in normal working condition.

Sensor life: 2 years

Protection: IP65

Explosion-proof: Exib IICT4

Dimension: l×b×h,mm: 135×64×33

Weight: About 250g

Tips: For TES handheld CO2 meter, please click here: CO2 Tester

HSTZQ169A Portable biogas Detectors with pump

Brief introduction

HSTZQ169A portable biogas Detectors with pump, adopting NDIR detecting principle, is used to analyze the CH4 and CO2 during the biogas processing. At the same, with external PH sensor, it can also analyze the PH level of the biogas fluid. By combining tip detecting technology and simple operation, this device has the advantages of high accuracy, good stability and excellent craftwork etc.

Features:
-Adopting advanced low-consumption 16-digit MCU
-128*64 lattice display and humanization operation menu
-Self test function after being activated, self diagnosis and self renovation
-Intrinsically safe design to avoid explosion inside the device
-Double power design, charger and battery are all available
-Calibration points can be adjusted, so the user can calibrate it easily
-Advanced long-life NDIR gas sensor
-Audio, video and vibration alarm
-Low voltage alert
-Important setting used combination key to avoid faulty operation
-Simple self calibration program
-Adopting high-strength plastics with skid proof rubber,
-The housing is hi-strength, feel very nice.

Specifications:
Target gas:CH4 and CO2
Sampling method Pump sampling
Gas sensor: NDIR
Detecting range:CH4:0-100%vol;CO2:0-5%vol (Can be specified);

                        PH:0.0-14.0
Alarm level: The user can set it in the detecting range.
Error:CH4/CO2:<= +/-2% F. S; PH:+/-0.2PH
Response time:<30s
Indication: LCD displays the real time and status; Voice alarms
Working condition: Temperature: -20
°C-55°C; Humidity: <95%RH No dews
Air pressure: 86 kPa-106 k Pa
Power supply: Two pcs AA Batteries
Charging time: More than 2h with pump
Working time Not less than 8 hours in normal working condition.
Sensor life:2 years
Dimension: l*b*h, mm: 209X110X40
Weight: About 410g

Packing: 1PCS/CTN, CTN SIZE: 33*18*13CM, G.W.: 2.5KGS

   

HSTZQ169B Portable CO2 Detectors with pump

Brief introduction

HSTZQ169B portable CO2 Detectors with pump, adopting NDIR detecting principle, is used to analyze the CO2 during the biogas processing. By combining tip detecting technology and simple operation, this device has the advantages of high accuracy, good stability and excellent craftwork etc.
Features:
-Adopting advanced low-consumption 16-digit MCU
-128*64 lattice display and humanization operation menu
-Self test function after being activated, self diagnosis and self renovation
-Intrinsically safe design to avoid explosion inside the device
-Double power design, charger and battery are all available
-Calibration points can be adjusted, so the user can calibrate it easily
-Advanced long-life NDIR gas sensor
-Audio, video and vibration alarm
-Low voltage alert
-Important setting used combination key to avoid faulty operation
-Simple self calibration program
-Adopting high-strength plastics with skid proof rubber,
-The housing is hi-strength, feel very nice.

Specifications:
Target gas:CO2
Sampling method Pump sampling
Gas sensor: NDIR
Detecting range:0-1%VOL,0-5%VOL,0-15%,0-50vol%(Can be specified)
Alarm level:10%-80% F. S adjustable
Error CO2: <= +/-2% F. S;
Response time:<30s
Indication: LCD displays the real time and status; Voice alarms
Working condition: Temperature: -20
°C-55°C; Humidity: <95%RH No dews
Air pressure: 86 kPa-106 k Pa
Power supply: Two pcs AA Batteries
Charging time: More than 2h with pump
Working time Not less than 8 hours in normal working condition.
Sensor life:2 years
Dimension: l*b*h, mm: 209X110X40
Weight: About 410g

Packing: 1PCS/CTN, CTN SIZE: 33*18*13CM, G.W.: 2.5KGS

   

 

SPD200B/CO Gas detector of Carbon Monoxide
Measurement display: displays with 4 digit LCD
Operation temperature: -10~50°C (14~122°F)
Storing temperature: 0~40°C(32~104°C)
Operation humidity: 0~99%RH (relative humidity)
Storing humidity: 20%~80% RH (relative humidity)
Measuring range: 0~1000PPM
Resolution: 1PPM
Measurement error: ±5%
Over measurement range display: --OL--
Alarming method: acousto-optic alarming
Working principle of the sensor: electrochemistry sensor
The service life of the sensor: 2 years (it can be then replaced)
Power supply: 3×1.5V AAA alkaline batteries
Battery service life: about 100 hours of continuous use (when the backlight is off).
Size: 172×51×26 (mm)

 

 

SPD201/O2 Gas detector of Oxygen, OXYGEN GAS ALARM DETECTOR
Measurement display: displays 4 digit LCD
Operation temperature: -10~40°C (14~104°F)
Storing temperature: 0~30°C (32~86°F)
Operation humidity: 0~99%RH (relative humidity)
Storing humidity: 20%~80% RH (relative humidity)
Measuring range: 0~25%(VOL)
Resolution: 0.1 %( VOL)
Measurement error: ±0.5%
Over measurement range display: --OL--
Alarming method: acousto-optic alarming
Working principle of the sensor: source cell sensor
The service life of the sensor: 2 years (it can then be replaced)
Power supply: 3×1.5V AAA alkaline batteries
Battery service life: about 100 hours of continuous use (when the backlight is off).
Size: 172×51×26 (mm)

   

SPD202/Ex COMBUSTIBLE GAS ALARM DETECTOR

SPD202 combustible gas detector can be used in hazardous areas indoors and outdoors, where combustible gas is produced, stored, used, etc., such as chemical, petroleum, metallurgy, oil depot, LPG (Liquefied Petroleum Gas) station , pharmaceutical, gas transmission and distribution, etc. to detect the leakage and show the leaking concentration with a digital display. This device can set two-level alarming value. The detector can raise the acousto-optic alarming when the detected concentration reaches the preset value.

1)        Detecting principle: catalytic combustion

2)        Detected gas: combustible gas

3)        Measurement range: 0-100% LEL (LEL: Low Explosion Level - the lowermost concentration of combustible gas to generate an explosion in air when meeting a naked flame)

4)        Resolution: 0.1%

5)        Error: ±2%

6)        Response time: <30s

7)        Operation temperature: -10℃~60

8)        Operation humidity: <99%RH

9)        Display mode: digital display with large LCD screen

10)    Alarming method: acousto-optic alarming

11)    Power supply: 4×1.5V AA batteries

12)    Current: <110mA (measuring status)

<15mA (non-measuring status)

   
 

MODEL: HSTDX70  single Gas detector of carbon monoxide

1. General

HSTDX70 is a kind of single gas or multiple gas detector/ alarm which can be optionally equipped with oxygen sensor, combustible gas sensor and any two or four sensors of different noxious gases, or a single gas sensor.

HSTDX70 has a very clear and large LCD with audible and visible alarm, and can detect any dangerous gas and send alarm to the operator in time for prevention even in very inimical work environment.

2. Technical performance and parameters

Features:

- Smart, portable and firm

- Audible and visible alarm

- Large screen digital and character display, instantaneous value, peak value and mean value available

- Self-checking for displaying, battery, sensor, audible and visible alarm at startup

- Regular light flashing and audible indication

- Distinct audible alarm

- Low maintenance cost

- 1, 2, 3 or 4 kinds of gas detecting supported

Technical performance and parameters

Gas for detect: carbon monoxide in the air (CO)
Range:0-999ppm
Precision: <± 5% (F.S)
Least count: 1ppm/0.1ppm
Response time: ≤ 25 sec

lithium ion rechargeable battery, 3.6V

Battery working period: 15 hours uninterrupted (combustible gas)

About 200 hours (except combustible gas)

Sensor service life: 3 years for combustible gas sensor, 2 years for oxygen and noxious gas sensor

Display: large screen LCD

Alarm: audible and visible alarm

Direct reading: instantaneous value, peak value, battery voltage, TWA, STEL

Ex-mark: Ex ibdIICT3

Protection degree: IP45

Work temperature: -10~40ºC

Work humidity: 5~90% RH

Size: 126mm (L) x 66mm (W) x 32mm (H)

Weight: 220g (with charger)

 

MODEL: HSTDX70  single Gas detector of carbon dioxide

1. General

HSTDX70 is a kind of single gas or multiple gas detector/ alarm which can be optionally equipped with oxygen sensor, combustible gas sensor and any two or four sensors of different noxious gases, or a single gas sensor.

HSTDX70 has a very clear and large LCD with audible and visible alarm, and can detect any dangerous gas and send alarm to the operator in time for prevention even in very inimical work environment.

2. Technical performance and parameters

Features:

- Smart, portable and firm

- Audible and visible alarm

- Large screen digital and character display, instantaneous value, peak value and mean value available

- Self-checking for displaying, battery, sensor, audible and visible alarm at startup

- Regular light flashing and audible indication

- Distinct audible alarm

- Low maintenance cost

- 1, 2, 3 or 4 kinds of gas detecting supported

Technical performance and parameters

Gas for detect: carbon dioxide in the air (CO2)
Range:
0-100000ppm
Precision: <± 5% (F.S)
Least count: 0.01ppm
Response time: ≤ 50 sec

lithium ion rechargeable battery, 3.6V

Battery working period: 15 hours uninterrupted (combustible gas)

About 200 hours (except combustible gas)

Sensor service life: 3 years for combustible gas sensor, 2 years for oxygen and noxious gas sensor

Display: large screen LCD

Alarm: audible and visible alarm

Direct reading: instantaneous value, peak value, battery voltage, TWA, STEL

Ex-mark: Ex ibdIICT3

Protection degree: IP45

Work temperature: -10~40ºC

Work humidity: 5~90% RH

Size: 126mm (L) x 66mm (W) x 32mm (H)

Weight: 220g (with charger)

 

MODEL: HSTDX80  Gas detector of multi-gas

1. General

HSTDX80 is a kind of single gas or multiple gas detector/ alarm which can be optionally equipped with oxygen sensor, combustible gas sensor and any two or four sensors of different noxious gases, or a single gas sensor.

DX80 has a very clear and large LCD with audible and visible alarm, and can detect any dangerous gas and send alarm to the operator in time for prevention even in very inimical work environment.

2. Technical performance and parameters

Features:

- Smart, portable and firm

- Audible and visible alarm

- Large screen digital and character display, instantaneous value, peak value and mean value available

- Self-checking for displaying, battery, sensor, audible and visible alarm at startup

- Regular light flashing and audible indication

- Distinct audible alarm

- Low maintenance cost

- 1, 2, 3, 4 kinds of gas detecting supported from below table.

Main technical indexes:

Gas for detect

Range

Precision

Least count

Response time

Oxygen (O2)

0-30%Vol

±5% (F.S)

0.1%Vol

≤ 15 sec

Combustible gas (Ex)

0-100%LEL

±5% (F.S)

1%LEL

≤ 5 sec

Carbon monoxide (CO)

0-999ppm

±5% (F.S)

1ppm

≤ 25 sec

Hydrogen sulphide (H2S)

0-100.0ppm

±5% (F.S)

1ppm

≤ 30 sec

Sulfur dioxide (SO2)

0-100.0ppm

±5% (F.S)

0.1ppm

≤ 30 sec

Nitrogen monoxide (NO)

0-250ppm

±5% (F.S)

1ppm

≤ 60 sec

Nitrogen dioxide (NO2)

0-20ppm

±5% (F.S)

0.1ppm

≤ 25 sec

Chlorine (Cl2)

0-20ppm

±5% (F.S)

0.1ppm

≤ 30 sec

Ammonia (NH3)

0-100ppm

±5% (F.S)

1ppm

≤ 50 sec

Hydrogen (H2)

0-1000ppm

±5% (F.S)

1ppm

≤ 60 sec

Hydrogen cyanide (HCN)

0-50ppm

±5% (F.S)

0.1ppm

≤ 200 sec

Hydrogen chloride (HCl)

0-20ppm

±5% (F.S)

0.1ppm

≤ 60 sec

Carbon dioxide (CO2)

0-100000ppm

±5% (F.S)

0.01ppm

≤ 50 sec

Sensors: Oxygen and toxic gas for electrochemical type, combustible gas for the catalytic combustion

lithium ion rechargeable battery, 3.6V

Battery working period: 15 hours uninterrupted (combustible gas)

About 200 hours (except combustible gas)

Sensor service life: 3 years for combustible gas sensor, 2 years for oxygen and noxious gas sensor

Display: large screen LCD

Alarm: audible and visible alarm

Direct reading: instantaneous value, peak value, battery voltage, TWA, STEL

Ex-mark: Ex ibdIICT3

Protection degree: IP45

Work temperature: -10~40ºC

Work humidity: 5~90% RH

Size: 126mm (L) x 66mm (W) x 32mm (H)

Weight: 220g (with charger)

 

MODEL: HSTDX90  Standard Four in one gas detection

1. General

HSTDX90 is a kind of superior performance complex gas detection alarm, which can simultaneously detect EX, oxygen, carbon monoxide, hydrogen sulfide, or  other gas, it is used for safety checking before entering into a dangerous conditions or confined space at industrial.

HSTDX90 has a very clear and large LCD with audible and visible alarm, and can detect any dangerous gas and send alarm to the operator in time for prevention even in very inimical work environment 

HSTDX90 can detect Housing made of high strength engineering materials, composite elastic rubber materials from refined, high strength, feel good, and the waterproof, dust-proof, explosion-proof.

2. Technical performance and parameters

Features:

- Import sensor, stable and reliable performance
- The use of high-strength ABS plastic, composite materials, elastic rubber shell
- Sound, vibration, and the shade of red, yellow, two-alarm
- Large screen digital, character display, instantaneous, peak, average shows
- Very low maintenance costs
- Can support any one or four of the gas detection from below table.

Main technical indexes:

Gas for detect

Range

Precision

Least count

Response time

Oxygen (O2)

0-30%Vol

±5% (F.S)

0.1%Vol

≤ 15 sec

Combustible gas (Ex)

0-100%LEL

±5% (F.S)

1%LEL

≤ 5 sec

Carbon monoxide (CO)

0-999ppm

±5% (F.S)

1ppm

≤ 25 sec

Hydrogen sulphide (H2S)

0-100.0ppm

±5% (F.S)

1ppm

≤ 30 sec

Sulfur dioxide (SO2)

0-100.0ppm

±5% (F.S)

0.1ppm

≤ 30 sec

Nitrogen monoxide (NO)

0-250ppm

±5% (F.S)

1ppm

≤ 60 sec

Nitrogen dioxide (NO2)

0-20ppm

±5% (F.S)

0.1ppm

≤ 25 sec

Chlorine (Cl2)

0-20ppm

±5% (F.S)

0.1ppm

≤ 30 sec

Ammonia (NH3)

0-100ppm

±5% (F.S)

1ppm

≤ 50 sec

Hydrogen (H2)

0-1000ppm

±5% (F.S)

1ppm

≤ 60 sec

Hydrogen cyanide (HCN)

0-50ppm

±5% (F.S)

0.1ppm

≤ 200 sec

Hydrogen chloride (HCl)

0-20ppm

±5% (F.S)

0.1ppm

≤ 60 sec

Carbon dioxide (CO2)

0-100000ppm

±5% (F.S)

0.01ppm

≤ 50 sec

Sensors: Oxygen and toxic gas for electrochemical type, combustible gas for the catalytic combustion

lithium ion rechargeable battery, 3.6V

Battery working period: 15 hours uninterrupted (combustible gas)

About 200 hours (except combustible gas)

Sensor service life: 3 years for combustible gas sensor, 2 years for oxygen and noxious gas sensor

Display: large screen LCD

Alarm: sound, vibration, and both red and yellow colored light alarm

Direct reading: instantaneous value, peak value, battery voltage, TWA, STEL

Ex-mark: Ex ibdIICT3

Protection degree: IP45

Work temperature: -10~40ºC

Work humidity: 5~90% RH

Size: 130mm (L) x 70mm (W) x 32mm (H)

Weight: 210g (with charger)

( If you need prices, pictures without our warter mark, user manual or E-catalogue for above meters, please ask for at: xiushunjie@gmail.com )

For gas alarm separately, please click here: gas alarm

For gas valve, please click here: gas valve

For gas sensor, please click here: gas sensor