|
Functions
and features:
RC-30/RC-30A/RC-30B is a series of Temperature data logger with high
performance versus price ratio and big LCD to display working
status, exchange data with computer by USB port, low power
consumption, power supplied by lithium battery and also can be
supplied by the computer through the USB port when connected to the
computer. NTC sensor, start up the recording function by key
operation, recording cycle adjustable, alarm temperature upper and
lower limit can be set. The data software possesses data analysis
function, it lists files of type not only can show the data and draw
the curve analyses graphs, but also can show alarm signal of the
temperature exceeding point. The recorded data can be inquired,
saved, printed and output in Word format. It is mainly used in
locales such as refrigerator cars, deepfreeze, labs, greenhouses,
storage for tobacco, bavterin and blood, workshops, hospital, GMP
medicine workshops, agricultural seed cultivation, incubator, born,
museum, archives, cultural relic, paper making, air-conditioner,
etc.
Technical
parameters:
◆Temperature measuring range: External sensor:-40℃~70℃
Internal sensor: -30℃~50℃
◆Accuracy: ±0.5℃ when at -20℃~20℃; at other range, ±1℃
◆Resolution:0.1
◆Recording cycle: 2Seconds~24Hours continuously set, or
automatically
dustributed as per recording duration
◆Sensor: NTC
◆Real-time transfers: the Interval time (10s~ 24h) adjustable
◆Recording capacity: RC-30: 3900 points RC-30A: 8000 points
RC-30B: 16000 points
◆Applicable environment: Temperature: -30℃~50℃ Humidity:15%~85%
◆Data output: Connect the computer with the USB port to transfer
data
◆ Safe level: IP65 |
Functions and features:
RC-20/20A/20B is a series of temperature data logger with high
performance versus lower price ratio, which can exchange data with
computer by USB port, low power consumption, power supplied by
lithium battery and also can be supplied by the computer through the
USB port when connected to the computer. NTC sensor, start up the
recording function by key operation, current working status
displayed by indicator light glistening times, recording cycle
adjustable, alarm temperature upper and lower limit can be set. The
data software possesses data analysis function, it lists files of
type not only can show the data and draw the curve analyses graphs,
but also can show alarm signal of the temperature exceeding point.
The recorded data can be inquired, saved, printed and output in Word
format. It is mainly used in locales such as refrigerator cars,
deepfreeze, labs, greenhouses, storage for tobacco, bavterin and
blood, workshops, hospital, GMP medicine workshops, agricultural
seed cultivation, incubator, born, museum, archives, cultural relic,
paper making, air-conditioner, etc.
Technical parameters:
◆Temperature measuring range: External sensor:-40℃~70℃
Internal sensor: -30℃~50℃
◆Accuracy: ±0.5℃ when at -20℃~20℃; at other range, ±1℃
◆Resolution: 0.1
◆Recording cycle: 2Seconds~24Hours continuously set, or
automatically
dustributed as per recording duration
◆Sensor: NTC
◆Real-time transfers: the Interval time (10s~ 24h) adjustable
◆Recording capacity: RC-20: 3900 points RC-20A: 8000 points
RC-20B: 16000 points
◆Applicable environment: Temperature: -30℃~50℃ Humidity:15%~85%
◆Data output: Connect the computer with the USB port to transfer
data
◆Safe level:IP65 |
|
RC-100 (external probe tip)
General description:
RC-100 Temperature Recorder is widely used for the storage and
transportation of the foodstuff、medicine 、fresh and live goods. It
is used in the walks of life which are accordant with HACCP System
Certificate as well. Furthermore, it can be used in locales where
need Temperature supervision, such as labs. RC-100 Temperature
Recorder has features as following: stable performance、small
size、large data recording capacity、high accuracy、lower watt
consumption, etc.RC-100 Temperature Recorder has two types: internal
and external temperature sensors.
Main Technical Parameters:
Temperature measuring range: -40.0℃~120.0℃
Accuracy: ±0.2℃
Displaying resolution: 0.1
Recording cycle: Normal mode: 2 seconds~24hours continuable setting
Low watt consumption mode: 10seconds~24hours continuable setting
Recording capacity: 16000 points (Max.)
Applicable environment: Temperature: -35℃~70℃ Humidity: 15%~95% (No
condensate)
Power supply: One 2.4Ah 3.6V non- charge up lithium battery (can
keep working for almost 1~2 years as per application circumstances)
Data transmission: Exchange data with computer by RS-232 interface
Sensor: PT1000 Platinum resistance
◆ Safe level: IP65 |
RC-100 (internal probe tip)
General description:
RC-100 Temperature Recorder is widely used for the storage and
transportation of the foodstuff、medicine 、fresh and live goods. It
is used in the walks of life which are accordant with HACCP System
Certificate as well. Furthermore, it can be used in locales where
need Temperature supervision, such as labs. RC-100 Temperature
Recorder has features as following: stable performance、small
size、large data recording capacity、high accuracy、lower watt
consumption, etc.RC-100 Temperature Recorder has two types: internal
and external temperature sensors.
Main Technical Parameters:
Temperature measuring range: -40.0℃~120.0℃
Accuracy: ±0.2℃
Displaying resolution: 0.1
Recording cycle: Normal mode: 2 seconds~24hours continuable setting
Low watt consumption mode: 10seconds~24hours continuable setting
Recording capacity: 16000 points (Max.)
Applicable environment: Temperature: -35℃~70℃ Humidity: 15%~95% (No
condensate)
Power supply: One 2.4Ah 3.6V non- charge up lithium battery (can
keep working for almost 1~2 years as per application circumstances)
Data transmission: Exchange data with computer by RS-232 interface
Sensor: PT1000 Platinum resistance
◆ Safe level: IP65 |
|
DR-200A+ Temperature Data Logger
Functions and features:
DR-200A+ Temperature Data Logger is widely used for the storage and
transportation of the foodstuff, medicine, fresh and live goods. It
is used in industries, which are accordant with HACCP System
Certificate as well. Furthermore, it can be used in locales where
need Temperature supervision, such as labs. DR-200A+ Temperature
Data Logger has features as following: reliable performance, large
data recording capacity, high accuracy, easy-to-use, passwords
protection, data reservation after electricity being cut off, with
function to set user name and working site etc.
Specification:
◆ Panel size: 144×144 (mm)
◆ Installing size: 131.5×131.5 (mm)
◆ Whole product size: 144×144×83 (mm)
Technical Parameters:
◆ Temperature measuring range: -40℃~110℃
◆ Accuracy:±0.5℃when at -10℃~85℃; ±1℃ at others
◆ Resolution: 0.1
◆ Alarming Temperature Difference: 0~20℃(adjustable)
◆ Alarming output: buzzer and alarming relay
◆ Recording cycle: 1Min~24Hours (adjustable)
◆ Recording and measuring ways: one way
◆ Printing output: Mini-type pin printer output
◆ Power Supply: 12V DC~24V DC/12V AC~24V AC
◆ Startup delay: 0~6 hours (adjustable)
◆ Alarming delay: 0~90 minutes (adjustable)
◆ Recording capacity: 4500 points (MAX.)
◆ Alarming relay contact capacity: 8A/220VAC
Error status:
◆ Probe error: Blinkingly displays error code EE with buzzer
alarming when sensor occurs short circuit or open circuit. ERROR
indicator light on.after alarm delay the alarm relay connected and
the buzzer alarming.the alarming sound cann’t be canceled.
◆ Alarm when exceeding temperature limits: the displaying values
blink with buzzer alarming when measuring temperature ≥ setting
temperature + alarming temperature difference or measuring
temperature ≤ setting temperature - alarming temperature difference,
ALARM indicator light on, press
▼ key to cancel alarming sound; No
alarming sound when 2AXX is 0. |
RC-500 Double Channel Temperature Data Recorder
Main functions:
RC-500 Temperature Recorder is widely used for the storage and
transportation of the foodstuff, medicine, fresh and live goods. It
is used in the walks of life which are accordant with HACCP System
Certificate as well. Furthermore, it can be used in locales where
need Temperature supervision, such as labs. RC-500 Temperature
Recorder has features as following:dual-channel circular display of
temp. measurement, dual-channel temp. recording, test of battery,
stable performance, small size, large data recording capacity,high
accuracy andlower power consumption, etc.
Technical parameters:
◆Temperature measuring range: -40.0℃~+120.0℃
◆Accuracy of temp. measurement under room temp.:±0.2℃(-20℃~+30℃),
±0.5℃ (other ranges)◆Resolution: 0.1
◆External sensor: PT1000
◆Sensor fix-up: external, connet with two Φ9 five-core aviation
scokets
◆Accuracy: ±3% RH
◆Resolution: 0.1
◆Recording cycle: Normal mode 2 seconds~24 hours continuous set
Low power consumption mode: 10 seconds~24 hours continuous set
◆Recording capacity: Dual-channel Temperature: 8000 points
separately (Max)
◆Applicable environment: Temperature: -35℃~+70℃
Humidity: 0%~95%
◆Power supply: 2.4Ah 3.6V one non-chargeable lithium battery
(continuous work at 1~2 years, depend on specific conditions)
◆Data output: Connect the computer with RS-232 interface to transfer
data
◆Safe level: IP65 |
|
DR-200B Temperature Recorder
Functions and features:
DR-200B Temperature Recorder is widely used for the storage and
transportation of the foodstuff,medicine ,fresh and live goods. It
is used in the industries which are accordant with HACCP System
Certificate as well. Furthermore, it can be used in locales where
need Temperature supervision, such as labs. It has features as
following: reliable performance,large data recording capacity,high
accuracy,easy-to-use,passwords protection,alarming and recording
parameters adjustable, data reservation after electricity being cut
off, etc.
Specification:
◆ Panel size: 144×144 (mm)
◆ Installing size: 131.5×131.5 (mm)
◆ Whole product size: 144×144×83 (mmTechnical Parameters:
◆ Temperature measuring range: -40℃~+110℃
◆ Accuracy: ±0.5℃ when at -10℃~+85℃, ±1℃ at others
◆ Resolution: 0.1
◆ Alarming Temperature Difference: 1~20℃ (adjustable)
◆ Alarming output: buzzer + alarming relay
◆ Recording cycle: 1Min~24Hours (adjustable)
◆ Recording and measuring ways: one way
◆ Printing output: Mini-type thermal printer output
◆ Power Supply: 12V AC~24 V AC or 12V DC~24V DC
◆ Start-up delay: 0~6 hours (adjustable)
◆ Alarming delay: 0~90 minutes (adjustable)
◆ Recording capacity: 4500 points (MAX.)
◆ Alarming relay contact capacity: 10A/220VAC, 5A/30VDC
Error status:
Probe error: Blinkingly displays error code EE with buzzer alarming
when sensor occurs short circuit or open circuit. ERROR indicator
light on.
Alarm when exceeding temperature limits: the displaying values blink
with buzzer alarming when measuring temperature ≥ setting
temperature + alarming temperature difference or measuring
temperature ≤ setting temperature - alarming temperature difference,
ALARM indicator light on, press ▼ to cancel alarming sound. No alarm
when alarming temp. difference is 0.
Exceeding upper measuring limits: Blinkingly displays HH with buzzer
alarming, ALARM indicator light on, press ▼ to cancel alarming
sound.
Exceeding lower measuring limits: Blinkingly displays LL with buzzer
alarming, ALARM indicator light on, press ▼ to cancel alarming
sound.
Alarming output: Relay contact output |
|