ZDRS-200 |
PH/PPM(EC)/Temp. Monitor
The highly reliable constant read
monitors that hang on the wall, measures PH, Conductivity and
Temperature simultaneously. Specially designed to achieve high
accuracy for long time use. Supplied with probes.
|
|
|
|
|
Measuring Range |
0.00 - 14.00 PH 0 - 9990 ppm 5 - 35℃/(41-95 ℉) |
0.00 - 14.00 PH 0.0 - 10.0 EC 5 - 35℃/(41-95 ℉) |
|
|
0.01 PH 10 ppm 1 ℃/℉ |
0.01 PH 0.1 EC 1 ℃/℉ |
|
|
+/- 0.10 PH +/- 2% FS +/- 1 ℃/℉ |
+/- 0.10 PH +/- 2% FS +/- 1 ℃/℉ |
|
|
6.90/4.01 PH or 7.00/4.01 PH 1382 ppm 25℃/77℉ |
6.90/4.01 PH or 7.00/4.01 PH 6.7 EC 25℃/77℉ |
|
|
|
|
|
|

ZDRS-200A |
|
 |
PH/ORP/temperature inline monitor
|
Model |
PH-2612 |
|
Range |
PH:0.00~14.00
mV:0~±1999mV
℃:0~100℃ |
|
Resolution |
PH:0.01PH
mV:1mV
℃:0.1℃ |
|
Accuracy |
PH:±0.01PH
mV:±1mV
℃:±0.4℃ |
|
Calibration |
1point or
2point |
|
A
T C |
0~95℃ |
|
Power |
DC9V/100mA or
Rechargeable battery |
|
Operating Conditions |
Temperature: 5~60℃
Humidity:
95% maximum |
|
Dimensions |
136×110×34mm |
|
Weight |
228g |
|
|
 |
PH/Temperature inline monitor
|
Model |
PH-2622 |
|
Range |
PH:0.00~14.00
℃:﹣9.9~99.9℃
℉:16~210℉ |
|
Resolution |
PH :0.01PH
℃:±0。1
℃
℉:±1℉ |
|
Accuracy |
PH :±0.02PH
℃:±1
℃
℉:±2℉ |
|
Calibration |
1point or
2point |
|
Power |
AC110v or
AC230V±10% |
|
Operating Conditions |
Temperature: 5~60℃
Humidity: 95%
maximum |
|
Dimensions |
136×93×35mm |
|
Weight |
460g |
|
|

|
DM-1: In-Line Dual TDS Monitor
Measure the tap water coming in vs. the
purified water going out of your water filtration system at any
time.
FEATURES
-
Displays TDS levels of the feed
water and product water with in & out electrode probes.
-
Highly efficient and accurate
due to its advanced microprocessor technology.
-
Auto-Off function conserves
battery power. The unit shuts off automatically after 10
minutes of non-use.
-
Dual Range 0-9990 ppm (From 0 -
999 ppm the resolution is 1 ppm. From 1000 to 9990 ppm, the
resolution is 10 ppm, indicated by a blinking 'x10' image.)
-
Factory calibration: our meters
are calibrated with a 342 ppm NaCl solution. Meters can be
recalibrated with a mini-screwdriver.
-
Comes equipped with John Guest
Quick-Connect T-fittings as shown.
-
Installs quickly and easily.
SPECIFICATIONS
Range: 0-9990
ppm
Accuracy: ±2%
Cable Length: 24.5" (including sensor)
Fittings: 1/4" standard, also available with 3/8"
or 1/2"
Power source: 2 x 1.5V button cell batteries
(included)
Battery life: approx. 1000 hours of continuous use
Size: 7.6 x 2 x 4.7 cm (3 x .8 x 1.9 in.)
Weight: 79.4 g (2.8 oz.)
|
|

|
DM-2: Commercial In-Line Dual TDS
Monitor
Install on industrial systems such as
car washes, window washing, manufacturing, and food processing.
FEATURES
-
Highly efficient and accurate
due to its advanced microprocessor technology.
-
Displays TDS levels of the Feed
Water and Product Water with in & out electrode probes.
-
Auto-Off function conserves
battery power. The unit shuts off automatically after 20
seconds.
-
Dual Range - Measures from 0-999
ppm, with a resolution of 1 ppm. From 1000 to 9990 ppm, the
resolution is in 10 ppm increments, indicated by a blinking
'x10' image.
-
Factory calibration: our meters
are calibrated with a 342 ppm NaCl solution. Meters can be
recalibrated with a mini-screwdriver.
-
Comes equipped with 1/4 inch
John Guest Quick-Connect T-fittings as shown. Also available
with 3/8" fittings.
-
Installs quickly and easily.
Differences from the
DM-1:
-
Designed for
commercial/industrial applications.
-
Stronger, water-resistant
casing.
-
Calibration can be done
individually or simultaneously on each line.
-
Improved design, including an
extra large, easy-to-read LCD display.
-
Longer, waterproof, shielded
cables.
-
Variable mounting bracket.
SPECIFICATIONS
Range: 0-9990
ppm
Accuracy: ±2%
Cable Length: 46" (including sensor)
Calibration: Factory calibrated to NaCl 342 ppm.
Re-calibration can be done separately for each line, or
simultaneously for both.
Power source: 2 AAA batteries (included)
Battery life: over 1000 hours of continuous use
Size: 11.6 x 6.8 x1.8 cm (4.6 x 2.6 x .7in.)
Weight: 201.3 g (7.1 oz.)
|
|
 |
PHT-026 multi-parameter
5 IN 1
Water Quality Monitor
|
Model |
PHT-026 |
|
Measuring Range |
PH: 0.00~14.00 PH
℃: -50℃~70℃ (-58℉~158℉)
EC: 0.00~19.99EC
CF: 0.0~199CF
TDS: 10~19990ppm |
|
Resolution |
PH: 0.01PH
℃: 0.1℃(0.2℉)
EC: 0.01EC
CF: 0.1CF
TDS: 10 ppm |
|
Accuracy |
PH: ±0.1 PH
℃: 1.0℃
EC、CF、TDS: ±2%F.S |
|
Operating Temperature |
0℃~50℃ |
|
Automatic Temperature
Compensation |
0℃~50℃ |
|
Power Supply |
AC110~240V,
with rechargeable battery |
|
Dimensions |
155mm×86mm×22mm |
|
Weight |
230g |
|
|
 |
PHT-027 multi-parameter
6 IN 1
Water Quality Monitor
(With ORP than
PHT-026)
|
Model |
PHT-027 |
|
Measuring Range |
PH: 0.00~14.00 PH
℃: -50℃~70℃ (-58℉~158℉)
EC: 0.00~19.99EC
CF: 0.0~199CF
TDS: 10~19990ppm
mv: 0~±1999mV |
|
Resolution |
PH: 0.01PH
℃: 0.1℃(0.2℉)
EC: 0.01EC
CF: 0.1CF
TDS: 10 ppm
mv: 1mV |
|
Accuracy |
PH: ±0.1 PH
℃: 1.0℃
EC、CF、TDS: ±2%F.S
mv: ±0.1℅F·S±1digit |
|
Operating Temperature |
0℃~50℃ |
|
Automatic Temperature
Compensation |
0℃~50℃ |
|
Power Supply |
AC110~240V,
with rechargeable battery |
|
Dimensions |
155mm×86mm×22mm |
|
Weight |
230g |
|
|
 |
PH-100 Digital pH Controller
|
Model |
PH-100 |
|
Measuring range |
0.00~14.00PH |
|
Accuracy |
±0.02PH |
|
Resolution |
0.01PH |
|
Set Range |
3.50~10.50PH |
|
Relay contact |
5A/240VAC |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Display |
4-digital LED |
|
Input Impedance |
1012Ω |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
108×210×48 (mm3) |
|
Weight |
550g |
|
|
 |
ORP-200 Digital ORP Controller
|
Model |
ORP-200 |
|
Measuring range |
0~±1999mV |
|
Accuracy |
±0.1℅+2 digits |
|
Resolution |
1mV |
|
Output current |
-500~500mV |
|
Relay contact |
AC220V/5A |
|
Environment |
Temperature:0~50℃ Humidity<95% |
|
Display |
4-digital LED |
|
Input Impedance |
1012Ω |
|
Power Supply |
110Vor220V±10℅50/60Hz±2% |
|
Dimensions |
108×210×48(mm3) |
|
Weight |
550g |
|
|
 |
KL-201W Digital Waterproof pH
Controller
Applications: Aquariums, Aquacultures, Beverage, Fish Hatcheries,
Food Processing,
Photography, Laboratory, Paper Industry, Swimming Pool, Plating
Industry
Same function as
PH-201, but it is waterproof than PH-201.
|
Model |
KL-201W (waterproof) |
|
Measuring range |
0.00~14.00PH |
|
Accuracy |
±(0.1%+2 digits)
after calibration |
|
Resolution |
0.01PH
|
|
Set Range |
3.50~10.50PH |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
165mmx158mmx121mm |
|
Weight |
580g |
|
|
 |
PH-201 Digital pH Controller
Applications: Aquariums, Aquacultures, Beverage, Fish Hatcheries,
Food Processing,
Photography, Laboratory, Paper Industry, Swimming Pool, Plating
Industry
|
Model |
PH-201 |
|
Measuring range |
0.00~14.00PH |
|
Accuracy |
±(0.1%+2 digits)
after calibration |
|
Resolution |
0.01PH
|
|
Set Range |
3.50~10.50PH |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
150mm×85mm×40mm |
|
Weight |
580g |
|
|
 |
PH-203 Digital pH/ORP
Controller
Applications: Aquariums, Aquacultures, Beverage, Fish Hatcheries,
Food Processing, Photography, Laboratory, Paper Industry,
Swimming Pool, Plating Industry, Quality control, Water
Conditioning,
School & colleges.
|
Model |
PH-203 |
|
Measuring range |
PH |
0.00~14.00PH |
|
ORP |
0~±1999mV |
|
Accuracy |
PH |
±(0.1%+2 digits) after
calibration |
|
ORP |
±5 mV |
|
Resolution |
PH |
0.01PH |
|
ORP |
1mV |
|
Set Range |
PH |
3.50~10.50PH |
|
ORP |
0~1000mV |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
150mm×85mm×40mm |
|
|
 |
ORP-206 Digital ORP
Controller
Applications: Aquariums, Aquacultures, Beverage, Fish Hatcheries,
Food Processing, Photography, Laboratory, Paper Industry,
Swimming Pool, Plating Industry, Quality control, Water
Conditioning,
School & colleges.
|
Model |
ORP-206 |
|
Measuring range |
0~±1999mV |
|
Accuracy |
±5 mV |
|
Resolution |
1mV |
|
Set Range |
-500~500mV |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
150mm×85mm×40mm |
|
Weight |
580g |
|
|
 |
CD-208
Digital Conductivity Controller
Applications: Aquariums, Aquacultures, Beverage, Fish Hatcheries,
Food Processing, Photography, Laboratory, Paper Industry,
Swimming Pool, Plating Industry, Quality control, Water
Conditioning,
School & colleges.
|
Model |
CD-208 |
|
Measuring range |
0~1999us/cm,
0~199.9mS |
|
Accuracy |
±(1.5%+2 digits)
after calibration |
|
Resolution |
1us, 0.1mS |
|
Set Range |
0~1000us,
0~100.0mS |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
150mm×85mm×40mm |
|
|
 |
HL-233 LEVEL CONTROLLER
|
Model |
HL-233 |
|
Power Supply |
AC 220V 50Hz |
|
Environment |
Temperature: 0~50℃, Humidity<95% |
|
Power Consumption |
2
watts |
|
Dimensions |
150mm×85mm×42mm |
|
Weight |
690g |
The electronic level controller
with 2 sensors will automate aquarium water top off. Since safety is
our number one concern, we include two float switch sensors with our
electronic water level controller. The first float switch sensor
triggers the feed pump (sold separately) to maintain the desire
water level. The second float switch sensor ensures dependability
and offers overflow protection. Our water level controller can also
be used to protect pump from running dry. It can be utilized in
three ways :
1.In this mode the power supply will turn on if the water level in
the sump is low AND there is enough water in the storage tank. The
power supply will turn off if the water level in the sump is high
AND there is not enough water in the storage tank.
(View Operation
diagram, MODE A-1)
With this set up the power supply will turn on as soon as the water
level in the sump drops below the set level. The power supply will
turn off if the water level in the sump is high the set level.
(View Operation
diagram, MODE A-2)
2. The power supply will turn on when the level falls below the
minimal level of float sensor1 and will turn off when water rises
the set point of the flow sensor1. The float sensor2 acts as a
backup sensor in the event the float sensor1 is stuck. The level
controller will not allow the power supply to turn on if the water
level in the sump reaches the maximum level of float sensor2.
(view Operation
diagram, MODE B)
3. Immerse the sensor1 and sensor2 in the measured
solution(sump).With this set up the power supply will turn on when
both sensors detected that the water level is below the minimum
level and stop only when the water rises the maximum level of both
sensor.
(View Operation diagram, MODE
C) |
|
 |
HL-233T LEVEL CONTROLLER
(with temperature display)
|
Model |
HL-233T
|
|
Temp Range |
0~80℃ |
|
Resolution |
0.1℃ |
|
Accuracy |
±1℃ |
|
Environment |
Temperature: 0~50℃, Humidity<95% |
|
Power Supply |
AC 220V 50Hz |
|
Dimensions |
150mm×85mm×42mm |
|
Weight |
690g |
|
|
 |
PH-301 Digital pH Controller
|
Model |
PH-301 |
|
Measuring range |
0.00~14.00PH |
|
Accuracy |
±0.1%+2 digits |
|
Resolution |
0.01PH |
|
Set Range |
3.50~10.50PH |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
160mm×102mm×40mm |
|
Weight |
772g |
|
|
 |
PH-601 Digital pH/Temperature
Controller
|
Model |
PH-601 |
|
Measuring range |
PH |
0.00~14.00PH |
|
Temperature |
0~100℃ |
|
Accuracy |
PH |
±0.1%+2 digits |
|
Temperature |
±0.4℃ |
|
Resolution |
PH |
0.01PH |
|
Temperature |
0.1℃ |
|
Set
Range |
PH |
3.50~10.50PH |
|
Display |
4-digital LED |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
160mm×102mm×40mm |
|
 |
Digital pH/ORP Controller
|
Model
|
KL-803
|
|
Measuring range |
PH |
0.00~14.00PH |
|
ORP |
-1999~1999mV |
|
Accuracy |
PH |
±0.1%+0.02PH |
|
ORP |
±5 mV |
|
Resolution |
PH |
0.01PH |
|
ORP |
1mV |
|
Set Range |
PH |
3.50~10.50PH |
|
ORP |
-500~500mV |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Display |
double 4 LED display reading |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
160mm×102mm×40mm |
|
Weigh |
872g |
|
|
 |
PH-303 Digital pH/ORP
Controller
|
Model |
PH-303 |
|
Measuring range |
PH |
0.00~14.00PH |
|
ORP |
0~±1999mV |
|
Accuracy |
PH |
±0.1%+2 digits |
|
ORP |
±5 mV |
|
Resolution |
PH |
0.01PH |
|
ORP |
1mV |
|
Set Range |
PH |
3.50~10.50PH |
|
ORP |
0~1000mV |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
160mm×102mm×40mm |
|
|
 |
ORP-306
Digital ORP Controller
|
Model |
ORP-306 |
|
Measuring range |
0~±1999mV |
|
Accuracy |
±5 mV |
|
Resolution |
1mV |
|
Set Range |
-500~500mV |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
160mm×102mm×40mm |
|
Weight |
772g |
|
|
 |
CD-308
Digital Conductivity Controller
|
Model |
CD-308 |
|
Measuring range |
0~1999us/cm,
0~199.9mS |
|
Accuracy |
±1.5%+2 digits |
|
Resolution |
1us, 0.1mS |
|
Set Range |
0~1000us,
0~100.0mS |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
160mm×102mm×40mm |
|
|
 |
PH-018 Industrial Online pH
Controller
It is an accurate secondary instrument
with LED digital display. it is applicable to determine pH value of
water solution in departments of petroleum,chemical,medicine-produce
ect. Automatic temp.Compensation
|
Model |
PH-018 |
|
Measuring range |
0.00~14.00PH |
|
Accuracy |
±0.02PH |
|
Resolution |
0.01PH |
|
Output current |
4-20mA |
|
Automatic temperature
compensation |
0~100℃ |
|
Warning accuracy |
±0.02PH |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Display |
4-digital LED |
|
Input Impedance |
1012Ω |
|
Power Supply |
220V±10℅ 50Hz±2℅ |
|
Dimensions |
96×96×160(mm3) |
|
Weight |
950g |
 |
|
 |
ORP-019 Industrial On-line ORP
Controller
|
Model |
ORP-019 |
|
Measuring range |
0~±1999mV |
|
Accuracy |
±(0.1℅+2 digits)after calibration |
|
Resolution |
1mV |
|
Output current |
4-20Ma(max charge:50Ω) |
|
Relay contact |
two
220V5A |
|
Environment |
Temperature:0~50℃ Humidity<95℅ |
|
Display |
4-digital LED |
|
Input Impedance |
1012Ω |
|
Power Supply |
110Vor220V±10℅50/60Hz±5℅ |
|
Dimensions |
96×96×160(mm3) |
|
Weight |
950g |
|
|


 |
PH/ORP INDUSTRIAL ON-LINE CONTROLLER
PH/ORP-6658H
|
Power supply |
AC 220V(160-250V)50Hz |
|
Power unit |
<5W |
|
Accuracy |
0.01PH 1mV |
|
Measurement range |
0-14PH -999mV~+999mV |
|
Set point |
2 |
|
Environmental temperature |
0~50°C |
|
Display |
Four-level LED LCD
instructions |
|
Environmental humidity |
35-85%RH |
|
Parameters preservation |
10 years |
|
Output model |
ON/OFF 4-20mA |
|
Output capacity |
AC 250v/3A DC30V/3A
|
|
Input impedance |
≥1012Ω |
|
Insulation R |
≥10MΩ | |