SPECTRUM ANALYZER

SM5010

Features:
SM5010
spectrum analyzer is used for the early test in the development of electrical products, troubleshooting of CATV/MATV system as well as the test and trouble diagnosis of cellular phone/paging systems. Combined with the near field probes of Mz530, it can detect the missing fields of radio frequency.

Specifications

Input frequency response

0.15-1050MHz, 3dB

Display accuracy of
central frequency

+/-200KHz (frequency sweep width +200KHz)

Accuracy of mark frequency

+/-0.1% (frequency sweep width +100KHz)

Frequency display resolution

100KHz (4½ bit LED display)

Frequency sweep width

0.1MHz/div-100KHz/div with 1, 2 and 5 step system
And 0Hz/div (0 frequency sweep) Accuracy: +/-10% (each range)

Intermediate frequency bandwidth

20KHz and 400KHz

Video filter

(When on) 4KHz

Amplitude range

-107~+13dB

Reference level

-27dB~+13dB (10dB for every step) +/-2dB

Average noise level

-97dB(20KHz intermediate frequency width)

Display range of CRT screen

80 dB(10dB/div)

Display range of vertical display

+/-2dB (2 With attenuator) 250MHz signal

Input attenuator

0-40dB (4x10dB step) error: +/-1dB/10dB

Maximum input level

+10dBm,+25V DC(Input attenuator set at 0dB)
+20dBm (input attenuator set at 40dB)

Frequency stability

Over 150KHz/hour

Input jack type

BNC

Input impedance

50次

Power supply

220V/110V; +/-10%; 50Hz/60Hz

Others

DC output

+6V (for probe)

AM demodulation output

Load impedance ≡16次

SM5011

Features:
SM5011
spectrum analyzer is used for the early test in the development of electrical products, troubleshooting of CATV/MATV system as well as the test and trouble diagnosis of cellular phone/paging systems. Combined with the near field probes of Mz530, it can detect the missing fields of radio frequency.

SM5011 is equipped with a tracing signal generator, and in the combined use of spectrum analyzer/tracing signal generator, it can complete the work which cannot be done by other frequency sweep system, such as sweep generator/network analyzer, sweep generator/spectrum analyzer, and sweep generator/oscilloscope, etc.

Specifications

Input frequency response

0.15-1050MHz, 3dB

Display accuracy of
central frequency

+/-200KHz (frequency sweep width +200KHz)

Accuracy of mark frequency

+/-0.1% (frequency sweep width +100KHz)

Frequency display resolution

100KHz (4½ bit LED display)

Frequency sweep width

0.1MHz/div-100KHz/div with 1, 2 and 5 step system
And 0Hz/div (0 frequency sweep) Accuracy: +/-10% (each range)

Intermediate frequency bandwidth

20KHz and 400KHz

Video filter

(When on) 4KHz

Amplitude range

-107~+13dB

Reference level

-27dB~+13dB (10dB for every step) +/-2dB

Average noise level

-97dB(20KHz intermediate frequency width)

Display range of CRT screen

80 dB(10dB/div)

Display range of vertical display

+/-2dB (2 With attenuator) 250MHz signal

Input attenuator

0-40dB (4x10dB step) error: +/-1dB/10dB

Maximum input level

+10dBm,+25V DC(Input attenuator set at 0dB)
+20dBm (input attenuator set at 40dB)

Frequency stability

Over 150KHz/hour

Input jack type

BNC

Input impedance

50次

Power supply

220V/110V; +/-10%; 50Hz/60Hz

 

Tracing signal generator

Input frequency response

0.15-1050MHz, 3dB

Output level range

-50~+1dBm (4x10dB) +/-3dB

Output attenuator

0-40dB (4x10dB step) error: +/-1dB/10dB

Input jack type

BNC

Input impedance

50次

 

Others

DC output

+6V (for probe)

AM demodulation output

Load impedance ≡16次

 

SM5005

 Frequency range: 0.1-500MHz

 Output impedance: 50次

 Output jack: BNC

 Input capacitance: about 2PF

 Maximum input level: +10dBm (according to frequency range), DC voltage: 20V
  Power supply voltage:+6V DC Current:8mA(probe for magnetic field),24mA(probe for electric field)
Dimensions:40x19x195mm

 

Mz530 probes are ideal tools for detecting the electromagnetic fields of radio frequency. They include resistance probes, magnetic field probes and electric field probes. They are indispensable tools for test in pre-accreditation of electromagnetic interference. When the probes are used with spectrum analyzer or measurement receiving unit, they can be used to find or define the electromagnetic interference wave, and at the same time can be used to evaluate the EMI of PCBs and newly developed sample units. They can help users to evaluate the performance comparison of the transmitting field and after adding the shield. See the instruction manual of Mz530 for more details.

Specifications

Input frequency response

0.15-500MHz, 3dB

Display accuracy of central frequency

+/-200KHz (frequency sweep width +200KHz)

Accuracy of mark frequency

+/-0.1% (frequency sweep width +100KHz)

Frequency display resolution

100KHz (4½ bit LED display)

Frequency sweep width

0.1MHz/div-100KHz/div with 1, 2 and 5 step system.
And 0Hz/div (0 frequency sweep) accuracy: +/-10% (each range)

Intermediate frequency
bandwidth

20KHz and 400KHz

Video filter

(When on) 4KHz

Amplitude range

-107~+13dB

Reference level

-27dB~+13dB (10dB for every step) +/-2dB

Average noise level

-97dB(20KHz intermediate frequency width)

Display range of CRT screen

80dB(10dB/div)

Display range of
vertical display

+/-2dB (2 With attenuator) 250MHz signal

Input attenuator

0-40dB (4x10dB step) error: +/-1dB/10dB

Maximum input level

+10dBm,+25V DC(Input attenuator set at 0dB)
+20dBm (input attenuator set at 40dB)

Frequency stability

Over 150KHz/hour

Input jack type

BNC

Input impedance

50次

Power supply

220V/110V +/-10%; 50Hz/60Hz

 

Others

DC output

+6V (for probe)

AM demodulation output

Load impedance ≡16次

 

SM5006

Frequency range: 0.1-600MHz

 Output impedance: 50次

 Output jack: BNC

 Input capacitance: about 2PF

 Maximum input level: +10dBm (according to frequency range), DC voltage: 20V
  Power supply voltage:+6V DC Current:8mA(probe for magnetic field),24mA(probe for electric field)
Dimensions:40x19x195mm

 

Mz530 probes are ideal tools for detecting the electromagnetic fields of radio frequency. They include resistance probes, magnetic field probes and electric field probes. They are indispensable tools for test in pre-accreditation of electromagnetic interference. When the probes are used with spectrum analyzer or measurement receiving unit, they can be used to find or define the electromagnetic interference wave, and at the same time can be used to evaluate the EMI of PCBs and newly developed sample units. They can help users to evaluate the performance comparison of the transmitting field and after adding the shield. See the instruction manual of Mz530 for more details.

Specifications

Input frequency response

0.15-600MHz, 3dB

Display accuracy of central frequency

+/-200KHz (frequency sweep width +200KHz)

Accuracy of mark frequency

+/-0.1% (frequency sweep width +100KHz)

Frequency display resolution

100KHz (4½ bit LED display)

Frequency sweep width

0.1MHz/div-100KHz/div with 1, 2 and 5 step system.
And 0Hz/div (0 frequency sweep) accuracy: +/-10% (each range)

Intermediate frequency
bandwidth

20KHz and 400KHz

Video filter

(When on) 4KHz

Amplitude range

-107~+13dB

Reference level

-27dB~+13dB (10dB for every step) +/-2dB

Average noise level

-97dB(20KHz intermediate frequency width)

Display range of CRT screen

80dB(10dB/div)

Display range of
vertical display

+/-2dB (2 With attenuator) 250MHz signal

Input attenuator

0-40dB (4x10dB step) error: +/-1dB/10dB

Maximum input level

+10dBm,+25V DC(Input attenuator set at 0dB)
+20dBm (input attenuator set at 40dB)

Frequency stability

Over 150KHz/hour

Input jack type

BNC

Input impedance

50次

Power supply

220V/110V +/-10%; 50Hz/60Hz

 

Tracing signal generator

Input frequency response

0.15-500MHz, 3dB

Output level range

-50~+1dBm (4x10dB): +/-3dB

Output attenuator

0-40dB (4x10dB step) error: +/-1dB/10dB

Input jack type

BNC

Input impedance

50次

 

Others

DC output

+6V (for probe)

AM demodulation output

Load impedance ≡16次