Model
VC3165 - Precision Frequency Counter ¡¡
Channel A (0.01Hz ~ 50MHz)
Channel B (50MHz ~ 2.4GHz) ¡¡
Time Base: Short-Time Stability: ¡À 3 x
10-9/sec |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
|
|
Model
VC2000 - Frequency Counter This VC2000 is an intelligent multi-function instrument which measures Frequency, Pulse counting, Crystal. It has 4 step gate time, 5 range function select and 8 digits display. All functions depend on single CPU, A crystal controlled temperature circuit provides constant compensation for the temperature drifting. Technique specifications: A. Measurement 1. Input terminal There are 3 input terminals on this instrument: CHA. High frequency 50 MHz - 2,4000 MHz CHB. Low frequency 10Hz - 50 M Hz Crystal Oscilloscope: for crystal measurement
Gate Time: 0.1S,1.0S,5.0S, 10S Accuracy: Time base deviation X frequency +- 1 d Progressive Counting measurement 4 steps CHB input terminal resolution: +- 1d, counting frequency: 10Hz - 4Mhz Crystal measurement: Input Features: Input sensitivity for CHA 25mVrms/200m Vrms Input impedance: approx. 50 Ohm Max safety voltage 3 V Input sensitivity for CHB: No.2 range 25m Vrms/80 m Vrms No.3 range 10mVrms/30m Vrms Input impedance: approx. 1 M ohm ( less than 35 pF) Max Input safety voltage: 30V Time base: Short term stability: +- 3 X 10-9/second Long term stability: +- 2 X 10-5/Month Temperature: +- 2 X 10-5/10oC - 40o C Power: 110 - 220V Size: 270 X 215 X100 mm Weight: Approx. 1550 g. |
|||||||||||||||||||||||||||||||||||||||||||||||||||||||
¡¡
¡¡
¡¡
¡¡
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Specification
|
Display |
9
digit large green LED display,Overflow,Gate time, |
|||||
|
Frequency
Measurement |
||||||
|
Range |
0.1Hz
to 100MHz(A input),80MHz to 3.0G(C input) |
|||||
|
Gate
Time |
0.01Sec,0.1Sec,10Sec |
|||||
|
Resolution |
1nHz
to 10Hz |
|||||
|
Accuracy |
+/-Resolution
+/-Timebase Error +/-Count |
|||||
|
Input
Characteristics |
||||||
|
Terminal |
A,C |
|||||
|
Sensitivity |
A
Input:20mVrms,C Input:30mVrms |
|||||
|
Impedance |
A
Input: Mohm, Less than 40pF,C Input:50 ohm |
|||||
|
Max.Input
Voltage |
A
Input:250Vrms,C Input:3Vrms |
|||||
|
Attenuator |
A
Input:x1,x10 |
|||||
|
Low
PASS Filter |
A
Iput:100kHz,-3dB |
|||||
|
Multi
Function
for Input A |
||||||
|
period |
Range:10mSec
to 10 |
|||||
|
Totalize |
Range:5
Hz to 10MHz |
|||||
|
RPM |
6
RPM t 900 x106 RPM |
|||||
|
Time
base Characteristics |
||||||
|
Internal
Time base |
Frequency:100MHz
TCO(TCXO;Ooption) |
|||||
|
Frequency
Standard INPUT |
Frequency:10MHz |
|||||
|
External
Standard Input |
Frequency:10MHz |
|||||
|
General |
||||||
|
Power
Requirement |
115/230VAC
+/-10%,48 to 66Hz |
|||||
|
Operating
Temperature |
O
to 500C(Accuracy specified at 25 +/-50C) |
|||||
|
Dimension |
240(W)x270(D)x90(H)mm |
|||||
|
Weight |
Approx.2.5kg |
|||||
|
Standard |
Power
Cord, BNC cable, Fuse, INSTRUCTION Manual |
|||||
|
Optional
Accessories |
RS-232C
Software,RS-232C Cable |
|||||
|
Packing
Details
|
||||||
|
|
Q'ty |
Size(mm) |
N.W.(kg) |
G.W.(kg) |
Remark |
|
|
Inner
Packing |
1 |
305(W)x330(D)x165(H) |
|
2.5 |
|
|
|
Carton
Packing |
3 |
320(W)x560(D)x360(H) |
7.5 |
8.5 |
|
|
| ¡¡ | ¡¡ | ¡¡ | ¡¡ | ¡¡ | ¡¡ | ¡¡ |
|
|
|
FC 7150U/7015U |
|
|
|
|
||
|
|
|
||
|
|
|
||
|
|
|
||
|
|
|
||
Specifications
|
SPEC
|
MODEL
|
FC-7150U
|
FC-7015U
|
|
Frequency
Measurement |
Display |
9
digit large green LED display (Overflow,Gatetime,mHz,Hz,kHz,ns,µs
ms,s,Hold) |
|
|
Range |
0.1Hz~1.5GHz |
0.1Hz~100MHz |
|
|
Gate
time |
0.01sec,0.1sec,1sec,10sec |
||
|
Resolution |
1nHz~10Hz |
||
|
Accuracy |
+/-Resolution+/-time
base error+/-1court |
||
|
Input
Characteristics |
Terminal |
A.B,C |
A |
|
Sensitivity |
A,B
input:20mVrms,Cinput:30mVrms |
||
|
Impedence |
A,B
input:1MΩ<40pF,C input:50Ω |
||
|
Max.Voltage |
A,input:250Vrms,C
input:3Vrms |
||
|
Attenuator |
A,B
input:x1£¬x10 |
||
|
Slope
A,B |
+£¬-
selectable |
||
|
Trogger
A |
Preset
or Variable |
||
|
L.P.Fiter |
A,B
input:100kHz,-3dB |
||
|
Multi
Function
for input A |
Period |
Range:10ms~10s,Resolution:1ps~1ns
Accuracy:+/-Resolution+/-Trigger Error+/-1count |
|
|
Totalize |
Range:5Hz~30MHz,Count
capacity:0~999999999(Max) |
||
|
RPM |
6~900x100RPM |
||
|
Comparison
Function for input A,B |
Time
Interval(A¡¨²B) |
Range:0.1
s~10s LSD Display:100ns Resolution+/-LSD+/-Trigger Error Accuracy:+/-Reslution+/-1count |
|
|
Ratio(A/B) |
Range:A
input:0.1Hz~10MHz B input:0.1Hz~10MHz LSD display:AxN/B,N=1~1000
Accuracy:+/-1count of A+/-B Tigger Error+/-A |
||
|
Time
Base Characteristics
|
Internal
time base |
-Frequency:10MHz
TCO(TCXO:Option) -Aging Rate:<3x10-7/month -Temperature
Stability:<x10-6(0+500C) -Lime voltage:<1x10-7for
10%variation |
|
|
Frequency
Output |
Frequency:10MHz,amplitude:2.5Vp-p,
Impedance:approx.500Ω |
||
|
External
Input |
Frequency:10MHz,input
level:20mV~5Vrms, Impedance:approx.500Ω |
||
|
General
|
Power
Requirement |
AC115/230V
+/-10%(50/60Hz) |
|
|
Temp./Dimension |
0~500C(specified
at 250C)/225(W)x260(D)x80(H)mm |
||
|
Weight/Accessories |
Approx.2kg/Power
cord,BNC cable,Fuse,Manual |
||
|
The
model FC-1300 is a RF-Frequency Counter designed for system and bench
use with max 9 digits, resolution featuring RS-23C and GPIB interfaces
with full remote control capability. The frequency range is from 10Hz to
3GHz(Option 3;5GHz)and High speed, High resolution Measurements are
possible .it is also equipped with the measurement functions for period,
peak voltage and auto trigger, auto limiting test. The model FC-1300 is
suited for use in R&D sections and production line such as cellular
phone, personal radios, pagers and other equipment. |
FC-1300 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
Specifications
|
CHANNEL
1 |
Frequency
range |
10Hz~220MHz |
|
Resolution |
9
digits/sec |
|
|
Sensitivity
(impedance:50Ω) |
100KHz~100MHz:>-20dBm(22mVrms)100KHz~200MHz:>-13dBm(50mVrms) |
|
|
Max
input level |
5Vrms
MAX |
|
|
Input
conditioning |
Impedance:1MΩ
or 50Ω |
|
|
Trigger
level |
Auto
Trigger:Set level by percent of Signal level |
|
|
Measurements |
Period(usec),peak
voltage(+/-5Vmax,0.01 step) |
|
|
CHANNEL2 |
Frequency
range |
100MHz~3GHz |
|
Resolution |
9digits/sec |
|
|
Sensitivity |
100MHz~2GHz:>-32dBm |
|
|
Max
input level |
5Vrms
MAX |
|
|
Analysis |
|
Automatic
limit testing |
|
Gating
time |
|
0.1sec,0.5sec,1sec,10sec
selectable |
|
Time
base |
Internal |
Frequency:10MHz |
|
External |
Frequency:10MHz
Input |
|
|
Interface |
|
RS~232C,GPIB(Option1) |
|
Power |
|
100/120/220/230/VAC,50/60Hz |
|
Size
and Weight |
|
100mm(H)x210mm(W)x350mm(D),3.6kg |
|
Option |
|
Otion1:GPIB
Interface |