FREQUENCY COUNTER

¡¡

 

Model VC3165 - Precision Frequency Counter

¡¡

Channel A (0.01Hz ~ 50MHz)
Frequency Range: DC couple 0.01Hz to 100Hz
                            AC couple 100Hz to 50MHz
Sensitivity: AC: 100Hz ~ 50MHz < 50m Vrms
                 DC: 0.01Hz ~ 1Hz ¡Ü 500m Vp-p
                 1Hz ~ 100Hz ¡Ü 80m Vrms
Impedance: 1 Mohms
Attenuator: X1, X20
Max. Safety Voltage: 30V (DC/AC peak)
¡¡

Channel B (50MHz ~ 2.4GHz)
Frequency Range: from 50MHz to 2.4GHz
Sensitivity: 50MHz ~ 1.2GHz ¡Ü 50m Vrms
                1.2GHz ~ 2.4GHz > 80m Vrms
Coupling: AC only
Impedance: 50 ohms
Max. Safety Voltage: 3V

¡¡

Time Base: Short-Time Stability: ¡À 3 x 10-9/sec
                  Long-Time Stability: ¡À 2 x 10-5/month
                  Temperature Drift Coefficient: ¡À 1 x 10-5, 10¡ãC ~ 40¡ãC
                  Line Voltage Variation: ¡À 1 x 10-7 for line voltage ¡À 10%
Gate Time: continuously variable from 100ms to 10s
Display: 8 digits, 19 x 12.5mm LED display with steps, frequency, period, kHz/s and MHz/ms indication
Precision: standard time error (t) x frequency (f) ¡À 1d
Power Supply: 110V/220V ¡À 10%, 50Hz or 60Hz
Preheat Time: 20 min
Operation temperature: 0¡ãC ~ 50¡ãC, 10 ~ 90% RH
Storage Temperature: -40¡ãC ~ 60¡ãC, 5 ~ 90% RH
Weight: approx. 1.6kg
Dimensions: 270 x 215 x 100mm
Accessories: this manual, power cord, test probe

 

Model VC2000 - Frequency Counter

This VC2000 is an intelligent multi-function instrument which measures Frequency, Pulse counting, Crystal. It has 4 step gate time, 5 range function select and 8 digits display.

All functions depend on single CPU, A crystal controlled temperature circuit provides constant compensation for the temperature drifting.

Technique specifications:

A. Measurement

1. Input terminal

There are 3 input terminals on this instrument:

CHA. High frequency 50 MHz - 2,4000 MHz

CHB. Low frequency  10Hz - 50 M Hz

Crystal Oscilloscope: for crystal measurement

Step

Function

Frequency

Resolution

0.1 S

1.0 S

5.0 S

10 S

 

Frequency Measurement

2400MHz - 1000MHz

1 KHz

100Hz

100Hz

100Hz

990MHz - 100MHz

1 KHz

100Hz

10 Hz

10Hz

99 MHz - 50 MHz

1 KHz

100Hz

10Hz

10Hz

50 Mhz-4 Mhz

100Hz

10 Hz

1Hz

1 Hz

2

4 Mhz - 10 Hz

10 Hz

1 Hz

0.1 Hz

0.1Hz

3

4

Counting

Max 99999999

-

-

Crystal Oscillator Measurement

16M Hz -3.5 M Hz

10 Hz

1 Hz

1 Hz

1 Hz

Gate Time: 0.1S,1.0S,5.0S, 10S

Accuracy: Time base deviation X frequency +- 1 d

Progressive Counting measurement

4 steps CHB input terminal

resolution: +- 1d, counting frequency: 10Hz - 4Mhz

Crystal measurement:

Input Features:

Input sensitivity for CHA  25mVrms/200m Vrms

Input impedance: approx. 50 Ohm

Max safety voltage 3 V

Input sensitivity for CHB: No.2 range 25m Vrms/80 m Vrms

                            No.3 range 10mVrms/30m Vrms

Input impedance: approx. 1 M ohm ( less than 35 pF)

Max Input safety voltage: 30V

Time base:

Short term stability: +- 3 X 10-9/second

Long term stability: +- 2 X 10-5/Month

Temperature: +- 2 X 10-5/10oC - 40o C

Power: 110 - 220V

Size: 270 X 215 X100 mm

Weight: Approx. 1550 g.

¡¡

¡¡

¡¡

¡¡

 FC-3000

Frequency measuring range: 0.1Hz to 100MHz in A input, 80 MHz to 3.0GHz in C input.

Period,Total and RPM measurement for input A

9 Digit display with 0.01mHz resolution in 1 Sec(By Ext.Reference signal).

RS-232C serial interface function for communication with computer.

High sensitivity Extemal reference input function(¡Ý1.5Vrms).

Peciprocal technique for high resolution at low counting frequencies .

Self check function executed to perform a automatic self diagnosis of various counter function.

Push-scanning for selecting Function and Gate time.

Low-pass filter(100KHz,-3dB)installed for removing noise signsl in low frequency measuring.

AC/DC coupling function(Selectable AC/CD Coupling)

10:1 Input Attenuation(Selectablex1/x10 Attenuator)

Data hold function

Specification

Display

9 digit large green LED display,Overflow,Gate time,
mHz,Hz kHz,MHz,ns,us,ms,HOLD

Frequency Measurement

Range

0.1Hz to 100MHz(A input),80MHz to 3.0G(C input)

Gate Time

 0.01Sec,0.1Sec,10Sec

Resolution

1nHz to 10Hz

Accuracy

+/-Resolution +/-Timebase Error +/-Count

Input Characteristics

Terminal

A,C

Sensitivity

A Input:20mVrms,C Input:30mVrms

Impedance

A Input: Mohm, Less than 40pF,C Input:50 ohm

Max.Input Voltage

A Input:250Vrms,C Input:3Vrms

Attenuator

A Input:x1,x10

Low PASS Filter

A Iput:100kHz,-3dB

Multi Function for Input A

period

Range:10mSec to 10
Resolution:1pSec deending on gate time and Input signal
Accuracu:+/-Resolution+/-Trigger+/-1Cout

Totalize

Range:5 Hz to 10MHz
Count capacity:0 to 999999999(Max.)

RPM

6 RPM t 900 x106 RPM

Time base Characteristics

Internal Time base

Frequency:100MHz TCO(TCXO;Ooption)
Aging Rate: Less thanx5 10-6/month 
Temp.Stability: Less than 5x10-6(00C to +500C)
Line Voltage: Less than1x10-6/ for10%variation

Frequency Standard INPUT

Frequency:10MHz
Amplitude:1.5Vp-p
Impedance:Approx.600ohm

External Standard Input

Frequency:10MHz
Amplitude:1.5Vrms to 5Vrms
Impedance:Approx.600ohm

General

Power Requirement

115/230VAC +/-10%,48 to 66Hz

Operating Temperature

O to 500C(Accuracy specified at 25 +/-50C)

Dimension

240(W)x270(D)x90(H)mm

Weight

Approx.2.5kg

Standard
Accessories

Power Cord, BNC cable, Fuse,  INSTRUCTION  Manual

Optional Accessories

RS-232C Software,RS-232C Cable

Packing Details

 

Q'ty

Size(mm)

N.W.(kg)

G.W.(kg)

Remark

Inner Packing

1

305(W)x330(D)x165(H)

 

2.5

 

Carton Packing

3

320(W)x560(D)x360(H)

7.5

8.5

 

¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡ ¡¡

 

 

Frequency measuring range:0.1Hz~100MHz in A,B input 80MHz~1.5GHz in C input(7150U only)
Trigger level adjustment for input A
Separate and Common mode selectable for input A and B
Period and Total measurement for input A and B
Time interval and Ratio measurement for input A and B
Slope mode selectable for input A and B

FC 7150U/7015U

9 Digit display with 0.01mHz resolution in 1sec

 

RS-232C serial interface function for communication with computer(Option)

 

High sensitivity External reference input function(>20mvrms)

 

Microprocessor controlled

 

Reciprocal technique for high resolution at low counting frequencies

 

Specifications

SPEC

MODEL

FC-7150U

FC-7015U

Frequency Measurement

Display

9 digit large green LED display (Overflow,Gatetime,mHz,Hz,kHz,ns,µs ms,s,Hold)

Range

0.1Hz~1.5GHz

0.1Hz~100MHz

Gate time

0.01sec,0.1sec,1sec,10sec

Resolution

1nHz~10Hz

Accuracy

+/-Resolution+/-time base error+/-1court

Input Characteristics

Terminal

A.B,C

A

Sensitivity

A,B input:20mVrms,Cinput:30mVrms

Impedence

A,B input:1MΩ<40pF,C input:50Ω

Max.Voltage

A,input:250Vrms,C input:3Vrms

Attenuator

A,B input:x1£¬x10

Slope A,B

+£¬- selectable

Trogger A

Preset or Variable

L.P.Fiter

A,B input:100kHz,-3dB

Multi Function for input A

Period

Range:10ms~10s,Resolution:1ps~1ns Accuracy:+/-Resolution+/-Trigger Error+/-1count

Totalize

Range:5Hz~30MHz,Count capacity:0~999999999(Max)

RPM

6~900x100RPM

Comparison Function for input A,B

Time Interval(A¡¨²B)

Range:0.1 s~10s LSD Display:100ns Resolution+/-LSD+/-Trigger Error Accuracy:+/-Reslution+/-1count

Ratio(A/B)

Range:A input:0.1Hz~10MHz B input:0.1Hz~10MHz LSD display:AxN/B,N=1~1000 Accuracy:+/-1count of A+/-B Tigger Error+/-A

Time Base Characteristics

Internal time base

-Frequency:10MHz TCO(TCXO:Option) -Aging Rate:<3x10-7/month -Temperature Stability:<x10-6(0+500C) -Lime voltage:<1x10-7for 10%variation

Frequency Output

Frequency:10MHz,amplitude:2.5Vp-p, Impedance:approx.500Ω

External Input

Frequency:10MHz,input level:20mV~5Vrms, Impedance:approx.500Ω

General

Power Requirement

AC115/230V +/-10%(50/60Hz)

Temp./Dimension

0~500C(specified at 250C)/225(W)x260(D)x80(H)mm

Weight/Accessories

Approx.2kg/Power cord,BNC cable,Fuse,Manual

 

The model FC-1300 is a RF-Frequency Counter designed for system and bench use with max 9 digits, resolution featuring RS-23C and GPIB interfaces with full remote control capability. The frequency range is from 10Hz to 3GHz(Option 3;5GHz)and High speed, High resolution Measurements are possible .it is also equipped with the measurement functions for period, peak voltage and auto trigger, auto limiting test. The model FC-1300 is suited for use in R&D sections and production line such as cellular phone, personal radios, pagers and other equipment.

FC-1300

 

Wide frequency range CH 1:10Hz~220MHz CH 2:100MHz~3GHz(Option 3;5GHz)

High resolution and high speed measurement using expanding reciprocal technique

Possible to measure the period, peak voltage

Select the trigger level(Auto/Manual)

Built tn auto limit testing

Save and recall function

Interface to RS-232C,GPIB(Option 1;GPIB)

Soft rubber key

Bright easy to view display using fluorescent display tube

Specifications

CHANNEL 1

Frequency range

10Hz~220MHz

Resolution

9 digits/sec

Sensitivity (impedance:50Ω)

100KHz~100MHz:>-20dBm(22mVrms)100KHz~200MHz:>-13dBm(50mVrms)

Max input level

5Vrms MAX

Input conditioning

Impedance:1MΩ or 50Ω
coupling:AC or DC
LPF:100KHz,switchable
Attenuator:X1 or X10

Trigger level

Auto Trigger:Set level by percent of Signal level
Manual Trigger:Set level by absolute Voltage

Measurements

Period(usec),peak voltage(+/-5Vmax,0.01 step)

CHANNEL2

Frequency range

100MHz~3GHz

Resolution

9digits/sec

Sensitivity

100MHz~2GHz:>-32dBm
2GHz~3GHz:>-25dBm

Max input level

5Vrms MAX

Analysis

 

Automatic limit testing

Gating time

 

0.1sec,0.5sec,1sec,10sec selectable

Time base

Internal

Frequency:10MHz
Stability:Standard:0.5ppm.TCXO

External

Frequency:10MHz Input
level:0.2Vrsm~5Vrms@impedance 1kΩ
¡¡

Interface

 

RS~232C,GPIB(Option1)

Power

 

100/120/220/230/VAC,50/60Hz

Size and Weight

 

100mm(H)x210mm(W)x350mm(D),3.6kg

Option

 

Otion1:GPIB Interface
Option2:High stability OCXO(+/-x10-8)
Otion3:5GHz channel