TT-GSV1
Specifications:
Detecting gas: LPG, natural gas, and coal gas
Power supply: AC100V~AC240V
Power frequency: 50/60Hz
Rated load: <4W
Alarm thickness: LPG: 0.1~ 0.5%;
natural gas: 0.1~ 0.3%; coal gas 0.1~ 0.5%
Alarm volume:¡Ý85dB
Working environment: -10¡æ¡«50¡æ relative humidity <97£¥RH
Storage temperature: -25¡æ¡«55¡æ |
|
 |
TT-GS
Specifications:
Detecting gas: LPG, natural gas, and coal gas
Power supply: AC100V~AC240V
Power frequency: 50/60Hz
Rated load: <4W
Alarm thickness: LPG: 0.1~ 0.5%natural gas: 0.1~ 0.3%;
coal gas 0.1~ 0.5%
Alarm volume:¡Ý85dB
Working environment: -10¡æ¡«50¡æ relative humidity <97£¥RH
Storage temperature: -25¡æ¡«55¡æ |
|
 |
TT-KAB
(for professional high level
using)
Brief Introduction:
KAB gas alarm, is designed to detect the concentration
of combustible gas, adopts high-quality gas sensor with
advanced technology and superior craft. It provides
visual and audible signals when the gas concentration,
such as LPG, natural gas, coal gas etc., reaches the
preset level. It reminds you to take prompt favorable
action. You may start up other link equipment, like
opening windows or shutting off gas supply, to avoid
fire, explosion, suffocation, and other malignant
accidents.
Main feautures:
-Micro-processor controlled, stable and no distort.
-Audible and visual alarm at site provided.
-Ventilation and shut off gas supply.
-Abide by EN50194
Specifications:
-Working voltage: AC220V¡À15% 50Hz~60Hz
-Target gas: Combustible gas, such as LPG, natural gas,
coal gas etc.
-Consumption: ¡Ü3W
-Working condition: Temperature: 0¡æ¡«55¡æ Humidity: <95%RH
-Response time: ¡Ü30s
-Gas sampling: Natural diffusion
-Alarming level: 10%LEL
-Alarming method: Visual and audible
-Alarm sound: ¡Ý85dB
-Sensor life: >5 years
-Weight: About 420g
-Dimension: L¡ÁW¡ÁH 170mm¡Á100mm¡Á45mm |
|
 |
TT-KAC
(for professional high level
using)
Brief Introduction:
KAC carbon monxide alarm, is designed to
detect the
concentration of carbon monoxide, adopts high-quality
carbon monoxide sensor with advanced technology and
superior craft. It provides visual and audible signals
when the carbon monoxide concentration reaches the
preset level. It reminds you to take prompt favorable
action.
-Abide by EN50291
Specifications:
-Working power: DC9V battery
-Working condition: Temperature: -10¡æ¡«55¡æ Humidity:
<95%RH
-Response time: ¡Ü30s
-Gas sampling: Natural diffusion
-Alarming method: Visual and audible
-Alarm sound: ¡Ý85dB
-Sensor life: >5 years
-Weight: About: 420g
-Dimension: L¡ÁW¡ÁH 170mm¡Á100mm¡Á45mm
-Alarming level:
50ppm Between 60-90mins
100ppm Between 10-40mins
300ppm Less than 3mins |
|
 |
TT-GN suitable for
security system
Brief introduction:
GN gas alarm, is designed to detect the concentration of
combustible, explosive and toxic gases, adopts
high-quality gas sensor with advanced technology and
superior craft. It provides visual and audible signals
when the gas concentration reaches the presetting level.
It reminds you to take prompt action. You may start up
other link equipment, open windows or shut off gas
supply to avoid fire, explosion, suffocation, and other
malignant accidents.
Main feautures:
With MCU, reliable and accurate
Audible and visual alarming on spot
RS485 communications (Optional)
Specifications:
Working voltage: DC24V¡À10% or DC12V¡À10%
Target gas: LPG, natural gas, Carbon Monoxide
Sampling method: natural diffusion
Consumption: ¡Ü3W
Working condition: Temperature: 0¡æ¡«55¡æ Humidity: <95%RH
Response time: ¡Ü 30s
Warm-up time: 180s¡À5s
Resume time: ¡Ü30s
Preset alarm point: 10%LEL
Alarm method: Visual and audible
Alarm sound: ¡Ý70dB
Signal output: Passive output (10A 250V AC)
Sensor life: >5 years
Weight: ¡Ü200g
Dimension: h*d 48mm¡Á104mm
Protection grade: IP42
Relay output: Max.3A, 28VDC
Color: White
Optional function: RS485 communications |
|
 |
TT-KAD
(for professional high level
using)
Brief Introduction:
KAD carbon monxide alarm, is designed to detect the
concentration of carbon monoxide, adopts high-quality
carbon monoxide sensor with advanced technology and
superior craft. It provides visual and audible signals
when the carbon monoxide concentration reaches the
preset level. It reminds you to take prompt favorable
action.
Main feautures:
Fuel Cell Sensor
LCD indicates gas concentration
Comply with standard EN50291
Peak value memory
Specifications:
Working power: 2AA battery (3V)
Display: LCD and back light
Working condition: Temperature: -10¡æ¡«55¡æ Humidity:
<95%RH
Response time: ¡Ü30s
Gas sampling: Natural diffusion
Alarming method: Visual and audible
Alarm sound: ¡Ý85dB
Sensor life: >5 years
Weight: About: 420g
Dimension: L¡ÁW¡ÁH 170mm¡Á100mm¡Á45mm
Alarming level:
50ppm¡¡ Between 60-90mins
100ppm¡¡Between 10-40mins
300ppm¡¡Less than 3mins |
|
 |
TT-GE
401 Natural Gas 10%LEL
601 LPG 10%LEL
Brief Introduction:
GE plug-in gas alarm, is designed to
detect the
concentration of combustible and toxic gases or vapors,
adopts high-quality gas sensor with advanced technology
and superior craft. It provides visual and audible
signals when the gas concentration reaches the
presetting level, reminding you to take prompt favorable
action.
Specifications:
Working voltage: AC220¡À10% or AC110¡À10%
Target gas: LPG, natural gas and carbon monoxide
Consumption: ¡Ü3W
Working condition: Temperature: 0¡æ¡«55¡æ Humidity: <95%RH
Response time: ¡Ü30s automatic resume
Sampling method: natural diffusion
Alarming level:
Combustible gas: 10%LEL
CO 150ppm
H2 1000ppm
Alarming method: Visual and audible
Alarm sound: ¡Ý70dB
Weight: 230g
Dimension: L¡ÁW¡ÁH 123mm¡Á81mm¡Á44mm
 |
|
 |
TT-GD
401 Natural Gas 10%LEL
601 LPG 10%LEL
701 CO 150ppm CO
801 Hydrogen 1000ppm H2
Brief Introduction:
GD gas alarm, is designed to
detect the concentration of
combustible, explosive and toxic gases, adopts
high-quality gas sensor with advanced technology and
superior craft. It provides visual and audible signals
when the gas concentration reaches the presetting level.
It reminds you to take prompt action. You may start up
other link equipment, open windows or shut off gas
supply to avoid fire, explosion, suffocation, and other
malignant accidents.
Specifications:
Working voltage: AC220V/110V¡À15% or DC24V/DC12V
Target gas: Combustible gas and carbon monoxide
Consumption: ¡Ü3W
Working condition: Temperature: 0¡æ¡«55¡æ Humidity: <95%RH
Response time: ¡Ü30s automatic resume
Sampling Method: natural diffusion
Alarming level:
Combustible gas: 10%LEL
CO 150ppm
H2 1000ppm
Alarming method: Visual and audible
Alarm sound: ¡Ý80dB
Weight: about 270g
Dimension: L¡ÁW¡ÁH 126mm¡Á78mm¡Á37mm
Optional function: relay output and gas shut off valve
output. |
|
 |
TT-GH
401 Natural Gas 10%LEL
601 LPG 10%LEL
Key Specifications:
GH series gas leak alarm is a kind of wall-hung household
gas alarm designed to detect the concentration of
combustible and toxic gases or vapors,
Provides visual and audible signals when the gas
concentration reaches presetting level, remind you take
prompt favorable action, you may start up other link
equipment, ventilate gas or shut off gas supply to avoid
fire, explosion, suffocation, and other evil accident
Alarms are available for liquefied petroleum gas (LPG),
natural gas (methane), propane, hydrogen, town gas,
smoke
Can be installed at home and any other similar place
Working voltage: AC2 20V +/- 15%, 50Hz or DC 12V
Target gas: combustible gas
Power consumption: 3W
Temperature: 0-55 deg. C
Humidity: < 95%
Response time: 30s automatic resume
Gas sampling: natural diffusion
Preset alarm point:
Combustible gas: 10%LEL
CO 150ppm
H2 1,000ppm
Alarm method: visual and audible
Alarm sound: 70dB
Weight: 270g
Dimensions (L x W x H): 137 x 75 x 49mm
Optional functions: relay output and gas shut off valve
output |
|
 |
TT-GK easy for wire
connection
GK gas alarm, is designed to
detect the concentration of combustible, explosive and
toxic gases, adopts high-quality gas sensor with
advanced technology and superior craft. It provides
visual and audible signals when the gas concentration
reaches the presetting level. It reminds you to take
prompt action. You may start up other link equipment,
open windows or shut off gas supply to avoid fire,
explosion, suffocation, and other malignant accidents.
401 Natural Gas 10%LEL
601 LPG 10%LEL
¡¡
Specifications:
Working voltage: AC220V¡À15%
/ AC110V¡À15% 50Hz? or DC12V/DC24V
Consumption: ¡Ü3W
Working condition: Temperature: 0¡æ¡«55¡æ Humidity: <95%RH
Response time: ¡Ü30s automatic resume
Sampling method: natural diffusion
Alarming Method: visual and audible
Alarm sound: ¡Ý70dB
Weight: 300g
Dimension: L¡ÁW¡ÁH 135mm¡Á82mm¡Á41mm
Optional function: relay output and gas shut off valve
output |
3. They
are designed complying with EN50194 or EN50291 standard, which is
European standard.
¡¡
Question: I want to know what is life of electrochemical sensor and
it is one time use or not?
Semiconductor gas
sensor 5 years min.
Catalytic gas
sensor 3 years min.
Electrochemical gas
sensor 5 years min.
Yes, they are one
time use. When the sensor life is overdue, the user needs to
contact us to replace the gas sensor or replace the whole gas
detector unit.